(11 intermediate revisions by 2 users not shown) |
Line 1: |
Line 1: |
− | '''Draft Outline for Commissioning'''
| + | [https://halldweb.jlab.org/hdops/wiki/index.php/Fall_2014_Commissioning_Plan Hall D Official Fall 2014 Commissioning Plan] |
| | | |
− | =Review Sequence=
| + | [[Preparations for Internal Photon Beam Commissioning]] |
− | # Electron beam
| + | |
− | #* OSP and small internal review in order to power and map tagger magnet
| + | |
− | #* Transfer of tagger magnet operation to accelerator, so that it can be reviewed as part of ARR II (nominally Jan)
| + | |
− | # Photon beam
| + | |
− | #* Review of photon beamline (radiator to photon beam dump). Nominally scheduled for March, at least 3 months prior to beam delivery
| + | |
− | #* Items to be covered by this review include:
| + | |
− | #*# tagger hodoscope
| + | |
− | #*# tagger microscope
| + | |
− | #*# profile monitor -- <u>where does this go? (not considered by Photon Beam WG so far)</u>
| + | |
− | #*# active collimator
| + | |
− | #*# halo monitors
| + | |
− | #*# other photon beam monitors -- <u>pair spectrometer? total absorption counter?</u>
| + | |
− | # Experimental Equipment Hall D
| + | |
− | #* Experimental apparatus in Hall D (prior to use with beam)
| + | |
| | | |
− | = Equipment List=
| + | [[Draft Outline for Commissioning]] |
− | [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=2363 Commissioning Bullets] GlueX-doc-2363 | + | |
− | | + | |
− | =Electron beam=
| + | |
− | ==Goals==
| + | |
− | # Safely deliver electron beam to the electron beam dump <ref name="TN08033"> Abkemeier, E. et al., "Shielding Basis for hall D Complex," July 2008, JLAB-TN-08-033 </ref>
| + | |
− | | + | |
− | ==Assumptions==
| + | |
− | # Accelerator has qualified the machine protection system (MPS) and the personnel safety system (PSS) for the tagger building
| + | |
− | # Assume steel blocks (> 20" thick) are stacked in front of <u>the entrance to</u> the photon beam pipe to the <u>tagger</u> hall to prevent any direct beam spray from traveling down to Hall D.
| + | |
− | | + | |
− | ==Checklist at low current I~1uA, [[tune mode]] <ref name=TN07022> Freyberger, A. and Tiefenback, M., "Diagnostic Specifications for the 12 Gev Upgrade," 2007, JLAB-TN-07-022 </ref> ==
| + | |
− | # Check beam is centered on the beam dump
| + | |
− | # Scan position of beam over the area of the radiator
| + | |
− | # Check single rates at various positions in the tagger enclosure (electronic racks)
| + | |
− | # Check single rates at the location of the tagger microscope
| + | |
− | # Check single rates at the location of the tagger broad band hodoscope
| + | |
− | # Verify tagger magnet excitation curve matches predictions, e.g. for different beam energies
| + | |
− | # Verify controls for all beamline elements work as expected
| + | |
− | # Check radiation levels in the tagger hall <ref name="TN08033"/>
| + | |
− | <ol start="9">
| + | |
− | <li> Establish location in the hall for electronic racks safe from radiation </li>
| + | |
− | <li> Identify sources of background (scraping) in the hall. </li>
| + | |
− | <li> Check Fast Shutdown system </li>
| + | |
− | </ol>
| + | |
− | | + | |
− | ==Checklist at low current I < 100 nA, CW==
| + | |
− | # Verify proper operation of beam as in pulsed mode
| + | |
− | # Check single rates at various positions in the tagger enclosure (electronic racks)
| + | |
− | # Check single rates at the location of the tagger microscope
| + | |
− | # Check single rates at the location of the tagger broad band hodoscope
| + | |
− | # Identify sources of background (scraping) in the hall.
| + | |
− | # Check out amorphous ladder controls
| + | |
− | # Commission halo pmts located on the electron beam pipe to the dump (i.e. adjust HV settings)
| + | |
− | # Change radiators and check relative thicknesses using halo pmts
| + | |
− | # Use accelerator harp to determine beam centroid and width
| + | |
− | # Use amorphous ladder harp to verify beam centroid, width and halo
| + | |
− | | + | |
− | ==Checklist at high current I > <u>2 μA</u>, CW==
| + | |
− | # Verify proper operation of beam as in low current situation
| + | |
− | # Check single rates at various positions in the tagger enclosure (electronic racks)
| + | |
− | # Check single rates at the location of the tagger microscope
| + | |
− | # Check single rates at the location of the tagger broad band hodoscope
| + | |
− | # Check radiation levels in the tagger hall
| + | |
− | # Check radiation levels in Hall D
| + | |
− | # Check radiation levels in the tagger service building
| + | |
− | | + | |
− | ==Abnormal conditions==
| + | |
− | | + | |
− | # High radiation levels in any or all areas of interest
| + | |
− | # Accidental loss of power to vertical bend string
| + | |
− | # Accidental loss of power of tagger magnet
| + | |
− | # Accidental loss of vacuum
| + | |
− | # <u>Accidental motion of goniometer target frame into beam</u>
| + | |
− | | + | |
− | =Photon beam=
| + | |
− | ==Goals==
| + | |
− | # Determine characteristics of photon beam in Hall D
| + | |
− | # Safely deliver photon beam through the hall to the photon beam dump
| + | |
− | | + | |
− | ==Assumptions==
| + | |
− | # Accelerator has qualified the machine protection system (MPS) and the personnel safety system (PSS) for Hall D and the counting house
| + | |
− | # Delivery of electron beam through tagger to electron dump has been accomplished
| + | |
− | # Operation is assumed CW, but perhaps one should start with pulsed mode
| + | |
− | # Amorphous radiator installed with 10<sup>-5</sup> <u>radiation lengths</u> thickness, typical
| + | |
− | # Steel blocking photon beam pipe in tagger hall has been removed
| + | |
− | # Initially the solenoidal magnet is off
| + | |
− | | + | |
− | ==Notes==
| + | |
− | # We should identify all apertures along the beam line to be aware of possible locations for scraping
| + | |
− | | + | |
− | ==Checklist, current I < 100 nA==
| + | |
− | | + | |
− | ==Location: before active collimator==
| + | |
− | # Require profile monitor to be installed and operational
| + | |
− | # Require active collimator to be installed and operational
| + | |
− | # Require halo monitors 1 to be installed and operational upstream of cave wall
| + | |
− | # Check that detector elements in Hall D are off and prepared
| + | |
− | # Check profile of photon beam exiting the beam pipe into cave
| + | |
− | # Determine center of photon beam relative to photon beamline
| + | |
− | # Compare with response of active collimator
| + | |
− | # Use this exercise to calibrate active collimator response
| + | |
− | # Scan the electron beam over the face of the radiator to establish aperture and check that photon beam profile behaves as expected
| + | |
− | # Check feedback signals of active collimator to control system. (Once understood, these can be used in real time to correct the beam position on the collimator).
| + | |
− | # Study the stability of the beam with and without feedback from the active collimator
| + | |
− | # Equalize rates in halo counters located in front of the cave back wall
| + | |
− | # Check radiation levels inside the collimator cave
| + | |
− | # Establish possible locations for electronics
| + | |
− | # Check radiation levels in Hall D
| + | |
− | # Check radiation levels in the counting house.
| + | |
− | # Determine suitability of delivering beam into the hall before proceeding.
| + | |
− | | + | |
− | ==Location: exiting pair spectrometer==
| + | |
− | # Commission the ladder with the PS converter including the harp
| + | |
− | # Require halo monitors 2 to be installed and operational downstream of the PS
| + | |
− | # Perform a harp scan using the converter ladder
| + | |
− | # Measure intensity and energy distribution of photon beam using pair spectrometer fine and coarse arrays.
| + | |
− | # Determine rate sensitivity to movements of the electron beam on the radiator
| + | |
− | # Check radiation levels inside the collimator cave
| + | |
− | # Check radiation levels inside Hall D
| + | |
− | # Measure single rates of detectors (e.g. BCAL, FCAL, TOF)
| + | |
− | | + | |
− | ==Location: behind FCAL==
| + | |
− | | + | |
− | # Relocate profile monitor behind the FCAL?
| + | |
− | # Verify expected profile (projection of collimator) through the detector
| + | |
− | # Verify expected photon beam rate
| + | |
− | # Check radiation levels inside Hall D
| + | |
− | # Measure single rates of detectors (e.g. BCAL, FCAL, TOF)
| + | |
− | | + | |
− | ==Alignment of beam to target==
| + | |
− | # Install commissioning target and start counter
| + | |
− | # Check that photon beam is transmitted cleanly through target cell
| + | |
− | # Use start counter rates to verify the photon beam is centered on the target
| + | |
− | # Check singles rates of detectors (e.g. BCAL, FCAL, TOF)
| + | |
− | | + | |
− | =References=
| + | |
− | <references />
| + | |