Difference between revisions of "CDC prototype tilted"
From GlueXWiki
(Created page with "{| border="0" cellpadding="2" |+Hit threshold 10sigma, timing threshold 5sigma, pedestal as mean of 100 bins ending 3 before high threshold crossing |[[Image:tilt_constped_ratio...") |
|||
(9 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
+ | Scintillators above and below prototype, 49cm apart. Scintillator width is 13cm. | ||
+ | Prototype placed on lower scintillator with straws at 90 degrees to long axis of scintillators. | ||
+ | |||
{| border="0" cellpadding="2" | {| border="0" cellpadding="2" | ||
− | |+ | + | |+Hits in straw 17 |
− | |[[Image:tilt_constped_ratio.png|thumb|x250px| | + | |[[Image:tilt_constped_ratio.png|thumb|x250px|Ratios of integrated signal with prototype tilted and flat]] |
|[[Image:tilt_constped_flat.png|thumb|x250px|Prototype horizontal]] | |[[Image:tilt_constped_flat.png|thumb|x250px|Prototype horizontal]] | ||
|[[Image:tilt_constped_60deg.png|thumb|x250px|Prototype at 30 degrees to horizontal]] | |[[Image:tilt_constped_60deg.png|thumb|x250px|Prototype at 30 degrees to horizontal]] | ||
|[[Image:tilt_constped_45deg.png|thumb|x250px|Prototype at 45 degrees to horizontal]] | |[[Image:tilt_constped_45deg.png|thumb|x250px|Prototype at 45 degrees to horizontal]] | ||
+ | |} | ||
+ | |||
+ | {| border="0" cellpadding="2" | ||
+ | |+Tracked hits in straw 17 | ||
+ | |[[Image:tilt_constped_tracks_ratio.png|thumb|x250px|Ratios of integrated signal with prototype tilted and flat]] | ||
+ | |[[Image:tilt_constped_tracks_flat.png|thumb|x250px|Prototype horizontal]] | ||
+ | |[[Image:tilt_constped_tracks_60deg.png|thumb|x250px|Prototype at 30 degrees to horizontal]] | ||
+ | |[[Image:tilt_constped_tracks_45deg.png|thumb|x250px|Prototype at 45 degrees to horizontal]] | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border="0" cellpadding="2" | ||
+ | |+Tracked hits in straw 17, track also passes through straw 23 (same column) | ||
+ | |[[Image:tilt_constped_vtracks_ratio.png|thumb|x250px|Ratios of integrated signal with prototype tilted and flat]] | ||
+ | |[[Image:tilt_constped_vtracks_flat.png|thumb|x250px|Prototype horizontal]] | ||
+ | |[[Image:tilt_constped_vtracks_60deg.png|thumb|x250px|Prototype at 30 degrees to horizontal]] | ||
+ | |[[Image:tilt_constped_vtracks_45deg.png|thumb|x250px|Prototype at 45 degrees to horizontal]] | ||
+ | |} | ||
+ | |||
+ | |||
+ | The fits are not great but all err in the same direction. Calculated MPV errors are < 1%. By eye I would have picked the MPVs for the histograms below (45 degrees and flat, ~vertical tracked hits, 50 samples integrated) at 5.5 and 3.4 x10^3 giving a ratio of 1.6. The calculated ratio of fit MPVs was 1.64 and histogram means was 1.60. Geometrically it should be 1.45 (the pink line) as the scintillator widths allow tracks up to 15 deg each side of vertical. | ||
+ | {| border="0" cellpadding="2" | ||
+ | |+Tracked hits in straw 17, track also passes through straw 23 (same column) | ||
+ | |[[Image:tilt_constped_vtracks_h5.png|thumb|x250px|50 samples integrated with prototype tilted and flat]] | ||
|} | |} |
Latest revision as of 10:59, 9 February 2012
Scintillators above and below prototype, 49cm apart. Scintillator width is 13cm. Prototype placed on lower scintillator with straws at 90 degrees to long axis of scintillators.
The fits are not great but all err in the same direction. Calculated MPV errors are < 1%. By eye I would have picked the MPVs for the histograms below (45 degrees and flat, ~vertical tracked hits, 50 samples integrated) at 5.5 and 3.4 x10^3 giving a ratio of 1.6. The calculated ratio of fit MPVs was 1.64 and histogram means was 1.60. Geometrically it should be 1.45 (the pink line) as the scintillator widths allow tracks up to 15 deg each side of vertical.