Difference between revisions of "Coil Test Weekly Meeting 24-Jun-2011"
From GlueXWiki
m (Text replacement - "/halldweb1.jlab.org/" to "/halldweb.jlab.org/") |
|||
(One intermediate revision by one other user not shown) | |||
Line 16: | Line 16: | ||
*** Floyd's spreadsheet for modified taps lists inductance for 2 a,b,c,d: 1.08501, 0.6312, 0.66625, 0.92144 H | *** Floyd's spreadsheet for modified taps lists inductance for 2 a,b,c,d: 1.08501, 0.6312, 0.66625, 0.92144 H | ||
*** in pairs you get 1.71 and 1.59, ratio about 1.08 | *** in pairs you get 1.71 and 1.59, ratio about 1.08 | ||
− | *** | + | *** will we use one or two QD channels? |
** Danfysik fault sequencer and slow dump | ** Danfysik fault sequencer and slow dump | ||
** additional PLC and HMI programming | ** additional PLC and HMI programming | ||
− | *** network loss problem | + | *** network loss problem |
− | *** auto elog entries | + | *** auto elog entries failure |
** fast DAQ | ** fast DAQ | ||
** replace smaller UPS | ** replace smaller UPS | ||
Line 28: | Line 28: | ||
** anything else? | ** anything else? | ||
* Auxiliar tests | * Auxiliar tests | ||
− | ** more crate tests | + | ** Beni wants to do more crate tests |
* [[For_the_fourth_coil|To-do list]] for the next coil | * [[For_the_fourth_coil|To-do list]] for the next coil | ||
** measure UPS lifetime under operating conditions | ** measure UPS lifetime under operating conditions | ||
Line 35: | Line 35: | ||
* Preparing for moving into the hall | * Preparing for moving into the hall | ||
** permanent VME-based fast DAQ | ** permanent VME-based fast DAQ | ||
− | * [http:// | + | * [http://halldweb.jlab.org/mantisbt Mantis Task Tracker] |
** role in Hall D Online/Controls effort | ** role in Hall D Online/Controls effort |
Latest revision as of 10:38, 31 March 2015
Solenoid Coil Test Weekly Meeting
Location and Time
- Fri 24-Jun-2011 9:30 am ARC 231
Agenda
- Close out P6 solenoid equipment task
- Coil 2 status
- installation status
- cooldown timeline
- subcoil inductances and quench detector
- Floyd's spreadsheet for modified taps lists inductance for 2 a,b,c,d: 1.08501, 0.6312, 0.66625, 0.92144 H
- in pairs you get 1.71 and 1.59, ratio about 1.08
- will we use one or two QD channels?
- Danfysik fault sequencer and slow dump
- additional PLC and HMI programming
- network loss problem
- auto elog entries failure
- fast DAQ
- replace smaller UPS
- anything else?
- Documentation
- trip chains
- anything else?
- Auxiliar tests
- Beni wants to do more crate tests
- To-do list for the next coil
- measure UPS lifetime under operating conditions
- IRMIS at JLab
- filled with BNL "training" data
- Preparing for moving into the hall
- permanent VME-based fast DAQ
- Mantis Task Tracker
- role in Hall D Online/Controls effort