Difference between revisions of "Requirements for Controls Systems from various detector components"
From GlueXWiki
(→FCAL) |
(→Target) |
||
(5 intermediate revisions by the same user not shown) | |||
Line 21: | Line 21: | ||
# Cooling system control | # Cooling system control | ||
#* Valves, temperatures ???? | #* Valves, temperatures ???? | ||
+ | # Gas system control | ||
+ | #* Solenoid valve control | ||
+ | #* Flow and pressure readout for monitoring (2 base modules with serial ports) | ||
# Control of HV channels CAEN A1535 | # Control of HV channels CAEN A1535 | ||
#* Estimated 130 channels (Doc. 967-v6) | #* Estimated 130 channels (Doc. 967-v6) | ||
− | #Control of LV on preamp cards (MPV 8008 or CAEN A1518) | + | # Control of LV on preamp cards (MPV 8008 or CAEN A1518) |
#* Estimated 64 channels (WIENER) or 77 channels (CAEN) (Doc. 966-v4) | #* Estimated 64 channels (WIENER) or 77 channels (CAEN) (Doc. 966-v4) | ||
Line 43: | Line 46: | ||
# Motion control | # Motion control | ||
#* 3 motors to control the microscope | #* 3 motors to control the microscope | ||
− | + | # Magnet control | |
+ | #* 1 Serial line for control | ||
+ | #* 1 Gaussmeter for field readback through serial | ||
== Beamline == | == Beamline == | ||
Line 54: | Line 59: | ||
#* control the position of the total absorption counter | #* control the position of the total absorption counter | ||
# Sweeping Magnets | # Sweeping Magnets | ||
− | #* Control 1 PS for the big sweeping magnets | + | #* Control 1 PS for the big sweeping magnets through serial |
− | #* 1 Gaussmeter readout to measure the field in the sweeping magnet | + | #* 1 Gaussmeter readout to measure the field in the sweeping magnet (serial) |
== Pair Spectrometer == | == Pair Spectrometer == | ||
Line 61: | Line 66: | ||
# Control pair spectrometer magnet | # Control pair spectrometer magnet | ||
#* Serial port communication to the power supply | #* Serial port communication to the power supply | ||
− | #* 1 Gauss-meter to B-field measurement | + | #* 1 Gauss-meter to B-field measurement (serial) |
# HV/LV control | # HV/LV control | ||
#* Approximately 20 channels, too early to decide | #* Approximately 20 channels, too early to decide | ||
# Positioning of the converter | # Positioning of the converter | ||
#* 1 axis motion | #* 1 axis motion | ||
− | |||
== Start Counter == | == Start Counter == | ||
Line 82: | Line 86: | ||
== Target == | == Target == | ||
# Control of the cry system of the target | # Control of the cry system of the target | ||
− | #* Valve control (~ | + | #* Valve control (~5 valves) |
#* Temperature sensor readout (10 sensors) | #* Temperature sensor readout (10 sensors) | ||
#* Pressure sensor readout (10 sensors) | #* Pressure sensor readout (10 sensors) |
Latest revision as of 18:09, 8 December 2010
Contents
BCAL
- Readout and monitoring of temperature sensors
- Estimated ~10 input channels (from Elton, Fernando)
- Control of 70V Bias LV channels on SiPMs
- Estimated 144 channels ?????
- Control of 5V LV on amplifiers
- Estimated 96 channels ??????
FCAL
- Control of HV on CW bases (IU is taking care of most of this)
- Estimated 2800 channels (from Matt)
- Control and monitor thresholds
- Estimated 2800 channels (from Matt)
FDC
- Readout and monitoring of of temperature sensors :
- Estimated ~10 input channels (from Lubomir and Beni)
- Cooling system control
- Valves, temperatures ????
- Gas system control
- Solenoid valve control
- Flow and pressure readout for monitoring (2 base modules with serial ports)
- Control of HV channels CAEN A1535
- Estimated 130 channels (Doc. 967-v6)
- Control of LV on preamp cards (MPV 8008 or CAEN A1518)
- Estimated 64 channels (WIENER) or 77 channels (CAEN) (Doc. 966-v4)
CDC
- Readout and monitoring of of temperature sensors :
- Estimated ~10 input channels (from Lubomir and Beni)
- Control of HV channels CAEN A1535
- Estimated 24 negative and 24 positive channels (Doc. 967-v6)
- Control of LV on preamp cards (MPV 8008 or CAEN A1518)
- Estimated 16 channels (WIENER) or 18 channels (CAEN) (Doc. 966-v4)
Tagger
- Control of HV channels
- Estimated 310 channels (Fernando's table)
- Motion control
- 3 motors to control the microscope
- Magnet control
- 1 Serial line for control
- 1 Gaussmeter for field readback through serial
Beamline
- Goni control
- control 3 axis of motion of to position the crystal and it's orientation
- Harps
- 2 harps, one before the radiator, another one before the beam dump
- control 2 axis of collimator motion
- control the position of the total absorption counter
- Sweeping Magnets
- Control 1 PS for the big sweeping magnets through serial
- 1 Gaussmeter readout to measure the field in the sweeping magnet (serial)
Pair Spectrometer
- Control pair spectrometer magnet
- Serial port communication to the power supply
- 1 Gauss-meter to B-field measurement (serial)
- HV/LV control
- Approximately 20 channels, too early to decide
- Positioning of the converter
- 1 axis motion
Start Counter
- HV for start counter
- 40 HV channel control
TOF
- HV for TOF counter
- Control 168 channels of HV for TOF
Target
- Control of the cry system of the target
- Valve control (~5 valves)
- Temperature sensor readout (10 sensors)
- Pressure sensor readout (10 sensors)
- Control of the target gas
- Valve control (~5 valves)
- Pressure sensor readout (5 sensors)