+ | Thursday March23,2023 1pm | ||
+ | Presented - Tim, Fernando, Stephanie, Keith H., Sasha, Scot, Chris S, Vlad B., Arshak | ||
''' Topics for discussion''' | ''' Topics for discussion''' | ||
Line 22: | Line 25: | ||
* Distribution panels positioned in 4 quadrants of the FCAL dark box. 9 Radial cables connected from outside to each quadrant. | * Distribution panels positioned in 4 quadrants of the FCAL dark box. 9 Radial cables connected from outside to each quadrant. | ||
− | * Use 9x4 = 36 CAEN A7030N modules (add 2 modules | + | * Each distribution board feeds an array of 20x20 ECAL modules, i.e., one quadrant of the ECAL (layout modified) |
− | * | + | * Radial connector orientation: 5 vertical and 4 horizontal [https://halldweb.jlab.org/detectors/fcal2/patch_panels/hv_distribution.xlsx] |
− | + | * Use 9x4 = 36 CAEN A7030N modules (add 2 modules to provide the same layout of patch panels and symmetric distribution of HV cables over chains in dark room) | |
+ | * HV cables inside the dark box (from dist boards to dividers) are routed through chains (left, right. top, bottom) | ||
+ | Questions: | ||
+ | * Exact location of distribution panels (hole size in the FCAL box) | ||
+ | * Length of cables | ||
+ | * Insulation | ||
+ | '''LV distribution''' | ||
+ | * Powered by 2 MPOD modules, 2 x 2 = 4 cables | ||
+ | * Use four (?) distribution boards positioned near the ECAL (change location). Each board is connected to 20x20 ECAL modules. | ||
+ | * New type of the LV connector and LV cable (shielded cable connected the divider and distribution board) | ||
+ | * Mount the distribution board on the 'plastic' rectangular beam pipe (or chains) ? Should be rigid. | ||
+ | * Plug the cable from the MPOD directly to the PCB (?) | ||
+ | * Distribute 4 LV cables along the beam pipe (similar to signal cables) | ||
+ | |||
Latest revision as of 22:27, 23 March 2023
Meeting Time and Place =
Thursday March23,2023 1pm
Presented - Tim, Fernando, Stephanie, Keith H., Sasha, Scot, Chris S, Vlad B., Arshak
Topics for discussion
- 1) Design of HV distribution panels
- -Length of HV cables (inside the dark room)
- 2) Design of the LV distribution panels
- -Length of LV cables (inside the dark room)
- 3) Location of signal patch panel
Original layout the distribution boards and cables
HV distribution
- Distribution panels positioned in 4 quadrants of the FCAL dark box. 9 Radial cables connected from outside to each quadrant.
- Each distribution board feeds an array of 20x20 ECAL modules, i.e., one quadrant of the ECAL (layout modified)
- Radial connector orientation: 5 vertical and 4 horizontal [1]
- Use 9x4 = 36 CAEN A7030N modules (add 2 modules to provide the same layout of patch panels and symmetric distribution of HV cables over chains in dark room)
- HV cables inside the dark box (from dist boards to dividers) are routed through chains (left, right. top, bottom)
Questions:
- Exact location of distribution panels (hole size in the FCAL box)
- Length of cables
- Insulation
LV distribution
- Powered by 2 MPOD modules, 2 x 2 = 4 cables
- Use four (?) distribution boards positioned near the ECAL (change location). Each board is connected to 20x20 ECAL modules.
- New type of the LV connector and LV cable (shielded cable connected the divider and distribution board)
- Mount the distribution board on the 'plastic' rectangular beam pipe (or chains) ? Should be rigid.
- Plug the cable from the MPOD directly to the PCB (?)
- Distribute 4 LV cables along the beam pipe (similar to signal cables)
Need to order soon: HV and LV cables