− | + | *"model_name": "/group/halld/AIEC/utilities/CDC_control_ai/cpp/d_cdc_modelneeds/gpflow_params.pkl", #the model being used | |
− | "poll_time": 1, #update every minute | + | *"poll_time": 1, #update every minute |
− | "rec_scale": -1, #how often to recommend high voltage. negative means run N times. At -1 this makes poll time have no effect. | + | *"rec_scale": -1, #how often to recommend high voltage. negative means run N times. At -1 this makes poll time have no effect. |
− | "control_window": [2110.0, 2150.0], #the min and max voltage to set the CDC to | + | *"control_window": [2110.0, 2150.0], #the min and max voltage to set the CDC to |
− | "epics_trailing_window": 15, #how many seconds to look back when checking epics | + | *"epics_trailing_window": 15, #how many seconds to look back when checking epics |
− | "ideal_gcf": 0.1482670653025542, #ideal gain correction factor. Will be set on initialization (during HV scan) | + | *"ideal_gcf": 0.1482670653025542, #ideal gain correction factor. Will be set on initialization (during HV scan) |
− | "default_hvbi": 2.05663, #default high voltage board current. Will be set on initialization (during HV scan) | + | *"default_hvbi": 2.05663, #default high voltage board current. Will be set on initialization (during HV scan) |
− | "require_human": 0, #we will not require any human intervention | + | *"require_human": 0, #we will not require any human intervention |
− | "control_mask": "ALL", #we will be controlling the entire CDC | + | *"control_mask": "ALL", #we will be controlling the entire CDC |
− | "debug": 0, #we are not debugging | + | *"debug": 0, #we are not debugging |
− | "default_temp": 299.25, #default gas temperature. Will be set on initialization (during HV scan) | + | *"default_temp": 299.25, #default gas temperature. Will be set on initialization (during HV scan) |
− | "default_pressure": 100.022, #default atm pressure. Will be set on initialization (during HV scan) | + | *"default_pressure": 100.022, #default atm pressure. Will be set on initialization (during HV scan) |
− | "baseline_V":2125, #the baseline CDC voltage, acts as a fail safe when EPIC disappears | + | *"baseline_V":2125, #the baseline CDC voltage, acts as a fail safe when EPIC disappears |
− | "fail_safe_timeout":90, #how long to wait with epics gone to trigger the fail safe. Currently, does nothing as we are running once at the beginning | + | *"fail_safe_timeout":90, #how long to wait with epics gone to trigger the fail safe. Currently, does nothing as we are running once at the beginning |
− | "confidence_threshold":0.03, #gcf confidence threshold to trigger uncertainty correction | + | *"confidence_threshold":0.03, #gcf confidence threshold to trigger uncertainty correction - it is compared to (standard deviation / ideal_gcf) |
− | "UQcorrection":1 #if we are outside the training set enough we will control the cdc via the closest point of confidence | + | *"UQcorrection":1 #if we are outside the training set enough we will control the cdc via the closest point of confidence |
− | + |
Latest revision as of 16:05, 6 June 2022
- "model_name": "/group/halld/AIEC/utilities/CDC_control_ai/cpp/d_cdc_modelneeds/gpflow_params.pkl", #the model being used
- "poll_time": 1, #update every minute
- "rec_scale": -1, #how often to recommend high voltage. negative means run N times. At -1 this makes poll time have no effect.
- "control_window": [2110.0, 2150.0], #the min and max voltage to set the CDC to
- "epics_trailing_window": 15, #how many seconds to look back when checking epics
- "ideal_gcf": 0.1482670653025542, #ideal gain correction factor. Will be set on initialization (during HV scan)
- "default_hvbi": 2.05663, #default high voltage board current. Will be set on initialization (during HV scan)
- "require_human": 0, #we will not require any human intervention
- "control_mask": "ALL", #we will be controlling the entire CDC
- "debug": 0, #we are not debugging
- "default_temp": 299.25, #default gas temperature. Will be set on initialization (during HV scan)
- "default_pressure": 100.022, #default atm pressure. Will be set on initialization (during HV scan)
- "baseline_V":2125, #the baseline CDC voltage, acts as a fail safe when EPIC disappears
- "fail_safe_timeout":90, #how long to wait with epics gone to trigger the fail safe. Currently, does nothing as we are running once at the beginning
- "confidence_threshold":0.03, #gcf confidence threshold to trigger uncertainty correction - it is compared to (standard deviation / ideal_gcf)
- "UQcorrection":1 #if we are outside the training set enough we will control the cdc via the closest point of confidence