− | # FDC t0 (keigo) | + | # FDC t0 [wire_timing_offsets] (keigo) |
+ | ## TDC-by-TDC t0 parameters are prepared for several PrimEx runs (with Field-ON) using Millepede procedure. 1M events analysis will suffice to generate the t0 parameters for 1 run. | ||
+ | ## 1 FDC wire plane has 2 TDCs, so there are 48 t0 parameters in total for 1 run. | ||
+ | ## [https://halldweb.jlab.org/wiki/images/b/b6/Res_081593.pdf Residual distributions before and after this t0 calibration for R081593 (PrimEx run)] | ||
+ | ## [https://halldweb.jlab.org/wiki/images/d/d9/Run_dep_081487.pdf Run dependence] |
Latest revision as of 22:23, 4 November 2021
- Instructions for Bluejeans meeting connection
- Meeting ID: 290664653
- To join via a Web Browser, go to the page [1] https://bluejeans.com/290664653.
Thu 11/4/2021 2pm
Agenda
- Detector performance
- CDC
- FDC
- Tracking
- Other
Minutes
- FDC t0 [wire_timing_offsets] (keigo)
- TDC-by-TDC t0 parameters are prepared for several PrimEx runs (with Field-ON) using Millepede procedure. 1M events analysis will suffice to generate the t0 parameters for 1 run.
- 1 FDC wire plane has 2 TDCs, so there are 48 t0 parameters in total for 1 run.
- Residual distributions before and after this t0 calibration for R081593 (PrimEx run)
- Run dependence