Difference between revisions of "Alternative readout"
From GlueXWiki
m (Text replacement - "http://argus.phys.uregina.ca/cgi-bin/private" to "https://halldweb.jlab.org/doc-private") |
|||
(15 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
+ | = References= | ||
+ | # Specifications and Evaluation of Bcal Readout Options [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=795 GlueX-doc-795] | ||
+ | # Response of FM pmts in magnetic field [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=712 GlueX-doc-712] and [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=1173 GlueX-doc-1173]. See also Antonelli et al., NIM A368 (1996) 628. | ||
+ | # Proposal for use of FM pmts in the outer section [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=731 GlueX-doc-731] | ||
+ | # Light collection in light guides [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=1077 GlueX-doc-1077] | ||
+ | # Dependence of resolution on granularity [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=659 GlueX-doc-659] and [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=1083 GlueX-doc-1083] | ||
+ | # BCAL Geometry specifications, see Figure 3 of [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=922 GlueX-doc-922] | ||
+ | # BCAL Number of optical photons, see pages 4-7 of [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=808 GlueX-doc-808] | ||
+ | # Pi0 and eta mass resolution [[Media:Pi0eta mass resol.png | Physics and Calorimeter Performance Metrics Fig. 10]] | ||
+ | |||
= Outline for Bcal using existing technologies = | = Outline for Bcal using existing technologies = | ||
− | * [ | + | * [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=832 Readout of the barrel calorimeter based on conventional photomultiplier tubes] (GlueX-doc-832, Jun 2007) |
* Issues that need to be considered (rough outline) | * Issues that need to be considered (rough outline) | ||
*# light guides and collection | *# light guides and collection | ||
Line 8: | Line 18: | ||
*#* planacons, wire mesh pmts | *#* planacons, wire mesh pmts | ||
*# magnetic fringe fields / shielding | *# magnetic fringe fields / shielding | ||
− | *#* [ | + | *#* [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=912 Magnetic fields at the location of pmts] |
*# cabling / number and sizes of cables / signal degradation | *# cabling / number and sizes of cables / signal degradation | ||
*#* cable differences between various detectors, e.g. HV | *#* cable differences between various detectors, e.g. HV | ||
Line 21: | Line 31: | ||
== Space Constraints== | == Space Constraints== | ||
− | * The Sketch below is to illustrate the space constraints for any light collection and readout system: | + | * The Sketch below is to illustrate the space constraints for any light collection and readout system. We note that this is the geometry that has been presented at reviews; the 'current geometry' given below has a somewhat different description: |
[[Image:Bcal_guides.gif]] <br> | [[Image:Bcal_guides.gif]] <br> | ||
+ | |||
+ | == Current Geometry == | ||
+ | The current geometry as visualized by ROOT (courtesy of Beni) is given below. All guides (both inner and outer) are represented by brown trapezoids (simple representation of a Winston Cone). The outer 'WC' are 10 cm long. The inner 'WC' are 5 cm long. The inner 'WC' are followed by 2x2x2 cm3 gray Al block to represent the SiPM. Six 'SiPMs' are butted and appear as a single radial piece connecting the 'WC's. Cables are simulated with material (not shown) that is routed quickly out and around the yoke. The Al plate (also gray) extends beyond the end of the Bcal (likely unchanged from previous longer Bcal geometry so should be updated). | ||
+ | |||
+ | [[Image:Endface of bcal wedge.gif]] <br> | ||
= Cathode coverage using fine-mesh pmts = | = Cathode coverage using fine-mesh pmts = | ||
<pre> | <pre> | ||
− | Nominal design | + | Nominal design with SiPMs and standard pmts |
full area Detectors cathode Fraction | full area Detectors cathode Fraction | ||
+ | inner 111.6 cm2 24 SiPM (circle) 1.13cm2 27.1 cm2 0.24 | ||
inner 111.6 cm2 24 SiPM 1.44cm2 34.6 cm2 0.31 | inner 111.6 cm2 24 SiPM 1.44cm2 34.6 cm2 0.31 | ||
outer 113.4 cm2 4 XP2262 D=4.4cm 60.8 cm2 0.53 | outer 113.4 cm2 4 XP2262 D=4.4cm 60.8 cm2 0.53 |
Latest revision as of 17:13, 24 February 2017
Contents
References
- Specifications and Evaluation of Bcal Readout Options GlueX-doc-795
- Response of FM pmts in magnetic field GlueX-doc-712 and GlueX-doc-1173. See also Antonelli et al., NIM A368 (1996) 628.
- Proposal for use of FM pmts in the outer section GlueX-doc-731
- Light collection in light guides GlueX-doc-1077
- Dependence of resolution on granularity GlueX-doc-659 and GlueX-doc-1083
- BCAL Geometry specifications, see Figure 3 of GlueX-doc-922
- BCAL Number of optical photons, see pages 4-7 of GlueX-doc-808
- Pi0 and eta mass resolution Physics and Calorimeter Performance Metrics Fig. 10
Outline for Bcal using existing technologies
- Readout of the barrel calorimeter based on conventional photomultiplier tubes (GlueX-doc-832, Jun 2007)
- Issues that need to be considered (rough outline)
- light guides and collection
- fiber light guides? re-evaluation of the granularity for the inner cal
- light detector
- planacons, wire mesh pmts
- magnetic fringe fields / shielding
- cabling / number and sizes of cables / signal degradation
- cable differences between various detectors, e.g. HV
- dark box / "wrapping of detector"
- presently no scheme has been worked out for any scenario
- impact on photon reconstruction [what is our current geometry?]
- what material is included for the WCs/SiPMs/cables?
- cost estimates
- light guides and collection
- Comments:
- Area of fibers cover 50% of the area of the end of the Bcal. Reduction is 2.
- Area of the output of the WC (1.2 cm2) reduces the readout by 4cm2/1.2cm2 = 3.3.
Space Constraints
- The Sketch below is to illustrate the space constraints for any light collection and readout system. We note that this is the geometry that has been presented at reviews; the 'current geometry' given below has a somewhat different description:
Current Geometry
The current geometry as visualized by ROOT (courtesy of Beni) is given below. All guides (both inner and outer) are represented by brown trapezoids (simple representation of a Winston Cone). The outer 'WC' are 10 cm long. The inner 'WC' are 5 cm long. The inner 'WC' are followed by 2x2x2 cm3 gray Al block to represent the SiPM. Six 'SiPMs' are butted and appear as a single radial piece connecting the 'WC's. Cables are simulated with material (not shown) that is routed quickly out and around the yoke. The Al plate (also gray) extends beyond the end of the Bcal (likely unchanged from previous longer Bcal geometry so should be updated).
Cathode coverage using fine-mesh pmts
Nominal design with SiPMs and standard pmts full area Detectors cathode Fraction inner 111.6 cm2 24 SiPM (circle) 1.13cm2 27.1 cm2 0.24 inner 111.6 cm2 24 SiPM 1.44cm2 34.6 cm2 0.31 outer 113.4 cm2 4 XP2262 D=4.4cm 60.8 cm2 0.53 Fine-mesh pmts Option. Note: Nine of the smallest 1" pmts bearly fit with housing over the inner face. Four 1.5" pmts can fit over the outer face. full area Detectors cathode Fraction inner 111.6 cm2 9 H6152-70 D=1.75cm 21.6 cm2 0.19 outer 113.4 cm2 4 H8409-70 D=2.7cm 22.9 cm2 0.20