Difference between revisions of "Minutes-7-14-2016"
(3 intermediate revisions by the same user not shown) | |||
Line 24: | Line 24: | ||
# fADC125 meeting (Naomi, Cody, Beni) | # fADC125 meeting (Naomi, Cody, Beni) | ||
# Other | # Other | ||
− | |||
− | |||
= Minutes = | = Minutes = | ||
Line 39: | Line 37: | ||
== FDC == | == FDC == | ||
+ | - Simon showed first plots about implementing the drift time in the FDC tracking. | ||
+ | |||
+ | - Lubomir studied the magnetic field effects with Garfield and showed that the effect of the avalanche deflection along the wire is equivalent to a wire rotation (of about 10deg for our field) w.r.t. avalanche position. The effect on the time-to-distance relation is equivalent to about 10% increase in the time scale. | ||
− | - | + | - Lubomir showed GENFIT results about the FDC resolution in magnetic field (all results so far presented were without magnetic field): there's strong dependence on momentum and is better than 200 microns at high momenta. There's more work needed on the alignment as seen from some systematics in the residuals shown above. |
Latest revision as of 19:36, 18 November 2016
July 14, 2016 Drift Chamber meeting
Connection
- Instructions for Bluejeans meeting connection
- Meeting ID: 290664653
Headline text
- To join via a Web Browser, go to the page [1] https://bluejeans.com/290664653.
Agenda
- Detector updates
- CDC update (Naomi/Mike/Beni)
- FDC update (Simon/Lubomir/Alex)
- First look using standard fitting code using FDC drift times
- Electron deflection in B field Garfield: perp. to wire, at 16deg., MC at 16deg., genfit results
- Drift time in B field genfit results
- Resolutions with genfit Momentum distributions,vs momentum, wire resolution
- Some systematics: [2], [3]
- NIM Papers
- fADC125 meeting (Naomi, Cody, Beni)
- Other
Minutes
Participants: Sean (NU), Mike (CMU) Eugene, Cody, Luke, Beni, Alexander A., Simon, and Lubomir (JLab).
CDC
- In the analyses meeting Mike reported already his studies on the CDC efficiency.
- Beni: Nick and Chris are cleaning/replacing the CDC HVB that had some issues during the last run due to some dust on them. We discussed possible origins of this dust: coming from the cooling tubes, air, or sucked by the magnetic field.
FDC
- Simon showed first plots about implementing the drift time in the FDC tracking.
- Lubomir studied the magnetic field effects with Garfield and showed that the effect of the avalanche deflection along the wire is equivalent to a wire rotation (of about 10deg for our field) w.r.t. avalanche position. The effect on the time-to-distance relation is equivalent to about 10% increase in the time scale.
- Lubomir showed GENFIT results about the FDC resolution in magnetic field (all results so far presented were without magnetic field): there's strong dependence on momentum and is better than 200 microns at high momenta. There's more work needed on the alignment as seen from some systematics in the residuals shown above.