Line 5: | Line 5: | ||
::: most minor issues have been fixed (DAC, trigger energy flow, ...) | ::: most minor issues have been fixed (DAC, trigger energy flow, ...) | ||
:: '''- New CTP firmware on tagger crates (106, 307, and A03)''' | :: '''- New CTP firmware on tagger crates (106, 307, and A03)''' | ||
− | ::: improves trigger timing by about 260 ns ( | + | ::: improves trigger timing by about 260 ns (FADC/CTP/SSP communication) |
::: do not update CTP firmware on other crates (may consider in the future, require some efforts) | ::: do not update CTP firmware on other crates (may consider in the future, require some efforts) | ||
:: '''- New SSP firmware for TAGM/TAGH crates''' | :: '''- New SSP firmware for TAGM/TAGH crates''' | ||
Line 23: | Line 23: | ||
::: more robust performance at high rate | ::: more robust performance at high rate | ||
::: consider to install on some crates (TAGH) if time permits | ::: consider to install on some crates (TAGH) if time permits | ||
+ | ::''' CAEN TDC''' (Beni) | ||
+ | |||
Latest revision as of 09:55, 31 October 2016
- Status of the firmware update
- - FADC250
- processing version C04 since last week (minor issues, will be updated shortly),
- control versions: 81 (TAGM/TAGH), 41 all other crates
- most minor issues have been fixed (DAC, trigger energy flow, ...)
- - New CTP firmware on tagger crates (106, 307, and A03)
- improves trigger timing by about 260 ns (FADC/CTP/SSP communication)
- do not update CTP firmware on other crates (may consider in the future, require some efforts)
- - New SSP firmware for TAGM/TAGH crates
- - New firmware versions for TIs (tip 61), TD (tdp 61)
- allows for busy distribution
- - New DSC firmware (version 0x10e)
- allows to set up bipolar thresholds
- installed on all crates except TOF
- is being currently tested
- updated config files to allow for positive thresholds (negative threshold values in config files)
- FADC 125
- New firmware (Cody)
- No readout issues anymore (so far), some features with settings (reading out) thresholds
- (Cody is trying to fix now)
- F1 TDC
- new version exists (is being tested)
- more robust performance at high rate
- consider to install on some crates (TAGH) if time permits
- CAEN TDC (Beni)
- - FADC250
- Testing tagger trigger "
- checking performance using play back
- correct trigger bit/channel assignment (VXS back plane was replaced, new CTP firmware version)
- minor issues with FADC/CTP/SSP communication (will be fixed)
- High-rate performance testing
- checked busy distributions from fadc 125 and 250 modules
- planning to repeat (perform more comprehensive tests) during this week
- (firmware was updated)
- Modifications in initialization libs and config files
- - new initialization and config parameters for FADC250
- - config files for the play back
- - additions/reorganization of config files ( per channel DSC thresholds, etc.; any sub-detector groups requests)
- - configurations for stand alone daq