+ | == Minutes == | ||
+ | |||
+ | # Announcements | ||
+ | #* Mark has tagged [https://phys12svn.jlab.org/repos/tags/ccdb_1.02 CCDB v1.02]. This primarily fixes bugs related to the use of different variations in JANA_CALIB_CONTEXT. | ||
+ | # Tracking | ||
+ | #* Naomi put together [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=2513 this document] which describes her investigations on correcting for B-field variations. She also redid her studies of radial B-field variation with finer resolution and found a maximum difference of 3 ns at maximum drift time. | ||
+ | #* The current time-to-distance tables for the CDC are generated assuming a magnetic field. Simon is being provided with tables corresponding to zero magnetic field. It was noted that the gas mixture in the CDC has a temperature around 296K. | ||
+ | #* | ||
+ | # Calorimetry | ||
+ | # Other systems |
Revision as of 16:31, 2 July 2014
GlueX Calibration Meeting
Wednesday, July 2, 2014
11:00 am, EDT
JLab: CEBAF Center, F326
Connection Using Bluejeans
- To join via Polycom room system go to the IP Address: 199.48.152.152 (bjn.vc) and enter the meeting ID: 630804895.
- To join via a Web Browser, go to the page [1] https://bluejeans.com/630804895.
- To join via phone, use one of the following numbers and the Conference ID: 630804895
- US or Canada: +1 408 740 7256 or
- US or Canada: +1 888 240 2560
- More information on connecting to bluejeans is available.
Agenda
- Announcements
- Status Update
- Tracking
- Cosmics Running
- CDC radial field drift-time diffs
- CDC drift-time & B field doc
- Calorimetry
- Other systems
- Simulations and Calibrations
Minutes
- Announcements
- Mark has tagged CCDB v1.02. This primarily fixes bugs related to the use of different variations in JANA_CALIB_CONTEXT.
- Tracking
- Naomi put together this document which describes her investigations on correcting for B-field variations. She also redid her studies of radial B-field variation with finer resolution and found a maximum difference of 3 ns at maximum drift time.
- The current time-to-distance tables for the CDC are generated assuming a magnetic field. Simon is being provided with tables corresponding to zero magnetic field. It was noted that the gas mixture in the CDC has a temperature around 296K.
- Calorimetry
- Other systems