Difference between revisions of "Private:Trigger Types"
From GlueXWiki
Line 12: | Line 12: | ||
: Generated by CTP in each crate. Possibility to generate the trigger for each BCAL module. | : Generated by CTP in each crate. Possibility to generate the trigger for each BCAL module. | ||
: ID of the 'fired' module is sent to the SSP along with the energy sum. | : ID of the 'fired' module is sent to the SSP along with the energy sum. | ||
− | : | + | : The trigger is sent from the SSP front pannel to the master TI. |
Revision as of 10:17, 2 August 2013
The main installation and trigger activities can be organized into the three main phases:
- Initial installation phase, where only a few crates with electronics are installed and connected to the sub-detector.
- Run stand alone DAC for each sub-detector. Start calibration of fadc pedestals, implementing calibration triggers and tuning trigger parameters
- Final Detector installation
- Detector Calibration with the Beam
BCAL
- Cosmics
- Generated by CTP in each crate. Possibility to generate the trigger for each BCAL module.
- ID of the 'fired' module is sent to the SSP along with the energy sum.
- The trigger is sent from the SSP front pannel to the master TI.
Detector | Trigger Types | Descriptions | Start Date |
---|---|---|---|
BCAL | Cosmics | Generated by CTP in each crate (for each BCAL module)
Send to SSP and subsequently to master TI </br> |
unknown |