Difference between revisions of "CDC tilted detectors summary"
From GlueXWiki
(Created page with "Prototype at 2100V, ~50/50 Ar/CO2 {| border="0" cellpadding="2" |Tilted detectors |[[Image:prototype_0deg.jpg|thumb|x250px|Tilted dete...") |
|||
Line 4: | Line 4: | ||
|[[Image:prototype_0deg.jpg|thumb|x250px|Tilted detectors ]] | |[[Image:prototype_0deg.jpg|thumb|x250px|Tilted detectors ]] | ||
|} | |} | ||
+ | |||
+ | <hr/> | ||
+ | <h3>50/50 mixed gas</h3> | ||
{| border="0" cellpadding="2" | {| border="0" cellpadding="2" | ||
− | |+ Integrated signal histograms | + | |+ Integrated signal histograms, central block of straws |
|[[Image:run_31962_integfitz.png|thumb|x150px|Horizontal ]] | |[[Image:run_31962_integfitz.png|thumb|x150px|Horizontal ]] | ||
|[[Image:run_31979_integfitz.png|thumb|x150px|Tilt 30° ]] | |[[Image:run_31979_integfitz.png|thumb|x150px|Tilt 30° ]] | ||
Line 84: | Line 87: | ||
|} | |} | ||
− | < | + | <h3>50/50 mixed gas, hits closer than 1mm to the wire</h3> |
{| border="0" cellpadding="2" | {| border="0" cellpadding="2" | ||
Line 94: | Line 97: | ||
The events in the noise peak in the amplitude histo do not reach the integration histo because the code ignores hits with a leading edge gradient less than 1. | The events in the noise peak in the amplitude histo do not reach the integration histo because the code ignores hits with a leading edge gradient less than 1. | ||
− | |||
{| cellpadding="2" border="1" cellspacing="0" | {| cellpadding="2" border="1" cellspacing="0" |
Revision as of 10:32, 21 February 2013
Prototype at 2100V, ~50/50 Ar/CO2
50/50 mixed gas
The paler lines are fits to a Landau dist, the darker lines are fits to a Landau-Gaussian convolution.
Ratio of MPVs of Landau fit to integration histograms for horizontal : 30° : 45° should be 1 : 1.15 : 1.41
The 45° and 0° runs were separated by 1/2 day; the 30° data was taken one week later.
Horizontal MPV | 30 degrees MPV | 45 degrees MPV | 30 degrees:horizontal | 45 degrees:horizontal | |||||
---|---|---|---|---|---|---|---|---|---|
Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss |
218 | 229 | 256 | 264 | 264 | 285 | 1.17 | 1.15 | 1.21 | 1.24 |
Horizontal MPV | 30 degrees MPV | 45 degrees MPV | 30 degrees:horizontal | 45 degrees:horizontal | |||||
---|---|---|---|---|---|---|---|---|---|
Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss |
5167 | 5301 | 6722 | 7446 | 7163 | 8113 | 1.30 | 1.40 | 1.39 | 1.53 |
50/50 mixed gas, hits closer than 1mm to the wire
The events in the noise peak in the amplitude histo do not reach the integration histo because the code ignores hits with a leading edge gradient less than 1.
Horizontal MPV | 30 degrees MPV | 45 degrees MPV | 30 degrees:horizontal | 45 degrees:horizontal | |||||
---|---|---|---|---|---|---|---|---|---|
Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss |
281 | 272 | 364 | 335 | 382 | 383 | 1.30 | 1.23 | 1.36 | 1.41 |
Horizontal MPV | 30 degrees MPV | 45 degrees MPV | 30 degrees:horizontal | 45 degrees:horizontal | |||||
---|---|---|---|---|---|---|---|---|---|
Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss | Landau | Landau-Gauss |
8604 | 7986 | 11658 | 10839 | 12339 | 11537 | 1.35 ± 0.04 | 1.36 | 1.43 ± 0.04 | 1.44 |
50/50 premix gas, unfiltered, label reads analysis 49.1 CO2, so this is 51/49 Ar/CO2
Horizontal MPV | 30 degrees MPV | 45 degrees MPV | 30 degrees:horizontal | 45 degrees:horizontal |
---|---|---|---|---|
Landau | Landau | Landau | Landau | Landau |
12970 | 15850 | 16217 | 1.22 ± 0.02 | 1.25 ± 0.03 |