Difference between revisions of "Minutes-4-19-2012"
From GlueXWiki
Line 22: | Line 22: | ||
== New results from the oxygen studies == | == New results from the oxygen studies == | ||
− | - Latest results | + | - Latest results linked above, starting from configuration #19: applying vacuum grease (Apiezon (L)) on two EPDM O-rings in the testing chamber resulted in a record low oxygen of 50ppm. Without Apiezon with the same configuration we had 405ppm. It means that we had significant oxygen contribution from the bottom cathode surface against the top O-ring on the spacer, that was eliminated with the grease. It turned out, however, the grease reacted with the EPDM |
== Production == | == Production == |
Revision as of 16:18, 19 April 2012
April 19, 2012 FDC meeting
Agenda
- New results from the oxygen studies (Lubomir)
- Production Construction Tracking (Dave)
- New procedures for package refurbishment
- First production cell with Apiezon and Viton O-rings
- Production status
- Engineering update (Bill)
- Electronics update (Chris)
- Tests with first package at 126 (Beni)
- Grounding
- Other