Difference between revisions of "GlueX Start Counter Meeting, November 17, 2011"
(notes as minutes) |
|||
Line 25: | Line 25: | ||
Talks can be deposited in the directory <code>/group/halld/www/halldweb1/html/talks/2011-4Q</code> on the JLab CUE. This directory is accessible from the web at https://halldweb1.jlab.org/talks/2011-4Q/ . You have to be a member of the "halld" Unix group to put files in this directory. | Talks can be deposited in the directory <code>/group/halld/www/halldweb1/html/talks/2011-4Q</code> on the JLab CUE. This directory is accessible from the web at https://halldweb1.jlab.org/talks/2011-4Q/ . You have to be a member of the "halld" Unix group to put files in this directory. | ||
+ | |||
+ | =Minutes= | ||
+ | |||
+ | start counter meeting minutes | ||
+ | |||
+ | - notes as minutes | ||
+ | |||
+ | Notes | ||
+ | |||
+ | |||
+ | puneet | ||
+ | chuck mark | ||
+ | |||
+ | got scintillators back from plastic craft | ||
+ | three that came back were crazed | ||
+ | 5% iso alcohol. naptha, | ||
+ | ordered replacement paddles | ||
+ | |||
+ | werner looked at it, some candidates | ||
+ | 1x4 or 1x5 favored | ||
+ | with 30 paddles | ||
+ | |||
+ | look at different products from H; mantis!!! | ||
+ | |||
+ | 2x4 would also work | ||
+ | |||
+ | actively explore using 4x4 as is | ||
+ | |||
+ | explore opening up diameter of sc array | ||
+ | |||
+ | look in catalog | ||
+ | |||
+ | werner back next week | ||
+ | |||
+ | simple light guide design better | ||
+ | |||
+ | two mistakes: | ||
+ | ignored recommendation, iso, naphta, petroleum extract | ||
+ | damaged three | ||
+ | one that came back was better than before | ||
+ | |||
+ | other mistake: sequescen | ||
+ | bend machine, polish | ||
+ | machine and polish and then bend better | ||
+ | |||
+ | ordered replacement from elgen | ||
+ | |||
+ | if choice: hard to find replacement for plastic craft, | ||
+ | |||
+ | made a demand that they consult better | ||
+ | |||
+ | will try to test some | ||
+ | |||
+ | overlap between rohacell | ||
+ | |||
+ | need to make target geometry consistent | ||
+ | |||
+ | need a tagged release | ||
+ | |||
+ | action item, update drawings | ||
+ | |||
+ | are flat sides polished? usually come smooth from manufacturer | ||
+ | |||
+ | one concern: puneet, straight portion, | ||
+ | |||
+ | this simulation | ||
+ | 24 paddles | ||
+ | |||
+ | working on rate and radiation dose using geant4 |
Revision as of 15:19, 17 November 2011
GlueX Start Counter Meeting
Thursday, November 17, 2011
10 am EST
JLab: CEBAF Center, Room F326/7
Agenda
- Announcements
- Review minutes from previous meeting
- Prototype Report
- SiPM configuration
- Contract Status
- Simulation Status [1]
Communication Information
Video Conferencing
- ESNet: 8542553
- EVO:
- Meeting URL: http://evo.caltech.edu/evoNext/koala.jnlp?meeting=292I2iMeMB9M9nDD9aD9
- Phone Bridge ID: 10 1295
Slides
Talks can be deposited in the directory /group/halld/www/halldweb1/html/talks/2011-4Q
on the JLab CUE. This directory is accessible from the web at https://halldweb1.jlab.org/talks/2011-4Q/ . You have to be a member of the "halld" Unix group to put files in this directory.
Minutes
start counter meeting minutes
- notes as minutes
Notes
puneet
chuck mark
got scintillators back from plastic craft three that came back were crazed 5% iso alcohol. naptha, ordered replacement paddles
werner looked at it, some candidates 1x4 or 1x5 favored with 30 paddles
look at different products from H; mantis!!!
2x4 would also work
actively explore using 4x4 as is
explore opening up diameter of sc array
look in catalog
werner back next week
simple light guide design better
two mistakes: ignored recommendation, iso, naphta, petroleum extract damaged three one that came back was better than before
other mistake: sequescen bend machine, polish machine and polish and then bend better
ordered replacement from elgen
if choice: hard to find replacement for plastic craft,
made a demand that they consult better
will try to test some
overlap between rohacell
need to make target geometry consistent
need a tagged release
action item, update drawings
are flat sides polished? usually come smooth from manufacturer
one concern: puneet, straight portion,
this simulation 24 paddles
working on rate and radiation dose using geant4