# Operation current density: | # Operation current density: | ||
#* PRIMEX 8.08"(20.54cm)gap: 564A/cm2=13500.Gauss | #* PRIMEX 8.08"(20.54cm)gap: 564A/cm2=13500.Gauss | ||
− | #* 3" gap: 527.5A/cm2=22950.Gauss (413 A/cm2 = 1.8 T) | + | #* 3" gap: 527.5A/cm2=22950.Gauss (413 A/cm2 = 1.8 T, linearity has to be checked) |
+ | # TOSCA installed in the Hall-D group | ||
+ | /group/halld/Software/tosca/ | ||
+ | #Field map (implementing to Hall-D Geant Simulation) | ||
+ | #* X: 0 - 24cm, 2 cm bin size (12 bins) | ||
+ | #* Y: 0 - 3.81 cm, 0.762 cm bin size (5 bins) | ||
+ | #* Z: 0 - 150 cm, 2.5 cm bin size (60 bins) |
Latest revision as of 10:09, 7 March 2011
- 18D36 magnet simulation with TOSCA
- Operation current density:
- PRIMEX 8.08"(20.54cm)gap: 564A/cm2=13500.Gauss
- 3" gap: 527.5A/cm2=22950.Gauss (413 A/cm2 = 1.8 T, linearity has to be checked)
- TOSCA installed in the Hall-D group
/group/halld/Software/tosca/
- Field map (implementing to Hall-D Geant Simulation)
- X: 0 - 24cm, 2 cm bin size (12 bins)
- Y: 0 - 3.81 cm, 0.762 cm bin size (5 bins)