This was the first dedicated Start Counter Meeting, as [https://mailman.jlab.org/pipermail/halld-pid/2010-November/000066.html announced] earlier. Nominally we will meet every other Thursday at 3:30 pm. | This was the first dedicated Start Counter Meeting, as [https://mailman.jlab.org/pipermail/halld-pid/2010-November/000066.html announced] earlier. Nominally we will meet every other Thursday at 3:30 pm. | ||
− | + | ==Prototype Status== | |
− | read-out | + | |
− | + | Werner and Lei reported on several items. | |
− | + | ||
+ | * Werner is leaning toward read-out with SiPM's, especially in light of the decision to go ahead and use them on the BCAL. | ||
+ | ** We need to check that the radiation dose upstream of the target but close to the beam line is operationally acceptable. | ||
+ | ** Werner has one at FIU to look at. | ||
+ | * New scintillator material has arrived at FIU. | ||
+ | ** Light output of the new counters will be evaluated with the SiPM. | ||
+ | * Bending studies are proceeding. The plan is to measure light output before and after bending on an older 5 mm counter. | ||
+ | |||
+ | personnel | ||
erik pooser working on the prototype hardware studies | erik pooser working on the prototype hardware studies | ||
− | • bending | + | • bending studies |
undergraduate, learning polishing | undergraduate, learning polishing | ||
• working on test stand to measure light output | • working on test stand to measure light output | ||
− | |||
− | |||
lei: talking to company that made light guides for central tof of clas12 | lei: talking to company that made light guides for central tof of clas12 | ||
company not a detector, acrylic furniture, vitale found them, can bend and polish light guides | company not a detector, acrylic furniture, vitale found them, can bend and polish light guides |
Revision as of 09:55, 19 November 2010
Location, Time
Friday, November 18, 2010
3:30 pm EST
JLab: CEBAF Center, Room F326/7
Conference Group: 800-377-8846, participant code: 77438230
ESNet: 8542553
EVO: direct meeting link, phone bridge ID: 7 7569
Slides: talks can be deposited in the directory /group/halld/www/halldweb1/html/talks/2010-11
on the JLab CUE (you have to be a member of the "halld" group). This directory is accessible from the web at https://halldweb1.jlab.org/talks/2010-11/ .
Agenda
- Announcements
- Start Counter Status: Werner
- MOU plans: all
Minutes
- FIU: Werner Boeglin
- JLab: Lei Guo, Mark Ito (chair), Simon Taylor
Announcements
This was the first dedicated Start Counter Meeting, as announced earlier. Nominally we will meet every other Thursday at 3:30 pm.
Prototype Status
Werner and Lei reported on several items.
- Werner is leaning toward read-out with SiPM's, especially in light of the decision to go ahead and use them on the BCAL.
- We need to check that the radiation dose upstream of the target but close to the beam line is operationally acceptable.
- Werner has one at FIU to look at.
- New scintillator material has arrived at FIU.
- Light output of the new counters will be evaluated with the SiPM.
- Bending studies are proceeding. The plan is to measure light output before and after bending on an older 5 mm counter.
personnel erik pooser working on the prototype hardware studies • bending studies undergraduate, learning polishing • working on test stand to measure light output
lei: talking to company that made light guides for central tof of clas12 company not a detector, acrylic furniture, vitale found them, can bend and polish light guides no problem for straight, scintillator, bent scintillator will find out, a sample sent need to find out radiation dose upstream of target 40 element detector in $200 in material, 10k$, 40 sipms plus light guides support structure we will start on mou