Difference between revisions of "GlueX Start Counter Meeting, November 18, 2010"
(add evo information) |
(notes as minutes) |
||
Line 15: | Line 15: | ||
# Start Counter Status: Werner | # Start Counter Status: Werner | ||
# MOU plans: all | # MOU plans: all | ||
+ | |||
+ | =Minutes= | ||
+ | |||
+ | simon, lei, mark | ||
+ | werner | ||
+ | |||
+ | construction mou | ||
+ | read-out leaning toward sipm's | ||
+ | werner has one | ||
+ | new scintillator material | ||
+ | erik pooser working on the prototype hardware studies | ||
+ | • bending scint | ||
+ | undergraduate, learning polishing | ||
+ | • working on test stand to measure light output | ||
+ | |||
+ | cut old 5 mm, light output measurement before and after bending | ||
+ | new counters: with sipm's | ||
+ | lei: talking to company that made light guides for central tof of clas12 | ||
+ | company not a detector, acrylic furniture, vitale found them, can bend and polish light guides | ||
+ | no problem for straight, scintillator, bent scintillator will find out, a sample sent | ||
+ | need to find out radiation dose upstream of target | ||
+ | 40 element detector in $200 in material, 10k$, 40 sipms | ||
+ | plus light guides | ||
+ | support structure | ||
+ | we will start on mou |
Revision as of 17:25, 18 November 2010
Location, Time
Friday, November 18, 2010
3:30 pm EST
JLab: CEBAF Center, Room F326/7
Conference Group: 800-377-8846, participant code: 77438230
ESNet: 8542553
EVO: direct meeting link, phone bridge ID: 7 7569
Slides: talks can be deposited in the directory /group/halld/www/halldweb1/html/talks/2010-11
on the JLab CUE (you have to be a member of the "halld" group). This directory is accessible from the web at https://halldweb1.jlab.org/talks/2010-11/ .
Agenda
- Announcements
- Start Counter Status: Werner
- MOU plans: all
Minutes
simon, lei, mark werner
construction mou read-out leaning toward sipm's werner has one new scintillator material erik pooser working on the prototype hardware studies • bending scint undergraduate, learning polishing • working on test stand to measure light output
cut old 5 mm, light output measurement before and after bending new counters: with sipm's lei: talking to company that made light guides for central tof of clas12 company not a detector, acrylic furniture, vitale found them, can bend and polish light guides no problem for straight, scintillator, bent scintillator will find out, a sample sent need to find out radiation dose upstream of target 40 element detector in $200 in material, 10k$, 40 sipms plus light guides support structure we will start on mou