Difference between revisions of "Comparison of radiation damage between FLUKA and Geant"
From GlueXWiki
Line 16: | Line 16: | ||
[[Image:neut_1MeVeq.jpg|450px|thumb|left| FLUKA neutrons ]] | [[Image:neut_1MeVeq.jpg|450px|thumb|left| FLUKA neutrons ]] | ||
− | ** | + | ** Particles per cm^2 per second in terms of 1-MeV equivalent neutrons in Si |
{| border="2" | {| border="2" | ||
Line 26: | Line 26: | ||
| Total | | Total | ||
|- | |- | ||
− | | | + | | 19.7 +- 1.3 |
− | | 0 | + | | 2.5 +- 0.8 |
− | | 0 | + | | 2.0 +- 0.1 |
− | | 0 | + | | 0.8 +- 0.7 |
− | | 0 | + | | 0.4 +- 0.4 |
− | | | + | | 25.5 +- 1.3 |
|} | |} | ||
* FLUKA geometry and input files | * FLUKA geometry and input files |
Revision as of 16:02, 21 September 2010
- Photon energy spectrum used in the simulations (photon flux corresponds to high-luminosity run)
- Silicon damage function used by FLUKA
- Particle spectra through the SiPM
- Particle fluences in terms of 1-MeV equivalent neutrons in Si
- Particles per cm^2 per second in terms of 1-MeV equivalent neutrons in Si
Neutrons | Protons | Pions | Electrons | Photons | Total |
19.7 +- 1.3 | 2.5 +- 0.8 | 2.0 +- 0.1 | 0.8 +- 0.7 | 0.4 +- 0.4 | 25.5 +- 1.3 |
- FLUKA geometry and input files