# Testing of new cal modules to measure light output and determine the range of phoelectrons expected.
+
# Testing of new cal modules to measure light output and determine the range of phoelectrons expected (George to propose test plan)
# Sensitivity to Hadronic radiation: Stepan to provide information on damage to SiPMs during NH3 pol target run. (Stepan)
+
# Detailed task list of everything that needs to be accomplished to flush out the use of SiPMs. (Elton, Fernando, Carl, Eugene...)
+
 
# Input/Decisions needed to finalize Bcal readout requirements (See also GlueX-doc-1373).
 
# Input/Decisions needed to finalize Bcal readout requirements (See also GlueX-doc-1373).
#* Specify the normalization and dynamic range for the number of photons/GeV in showers
+
#* Specify the normalization and dynamic range for the number of photons/GeV in showers (Andrei to summarize MC results)
#* Decide on specific grouping for SiPM sums
+
#* Decide on specific grouping for SiPM sums  
#* Possibility of using air gap for SiPM coupling
+
#* Possibility of using air gap for SiPM coupling to light guide (Elton to write up results)
 
#* Finalize shapes of "Winston guides"
 
#* Finalize shapes of "Winston guides"
  

Revision as of 14:44, 11 February 2010

Teleconference Time: 11:00 a.m. EST

  • ESNET and EVO session
  • Phone in CC F326 is 757-269-6337
  • Phone:
    • +1-800-377-8846 : US
    • +1-888-276-7715 : Canada
    • +1-302-709-8424 : International
    • then enter participant code: 77438230# (remember the "#"). Phone connection only upon request.

Items for followup from previous meeting

  1. Testing of new cal modules to measure light output and determine the range of phoelectrons expected (George to propose test plan)
  2. Input/Decisions needed to finalize Bcal readout requirements (See also GlueX-doc-1373).
    • Specify the normalization and dynamic range for the number of photons/GeV in showers (Andrei to summarize MC results)
    • Decide on specific grouping for SiPM sums
    • Possibility of using air gap for SiPM coupling to light guide (Elton to write up results)
    • Finalize shapes of "Winston guides"

Documents to Review

Tentative Agenda

  1. Announcements
  2. Review of Action Items
  3. Update - USM
    • First tests of SiPMs (Serguei)
  4. SiPM - update
  5. Light guides
    • For reference: top = 2.525 cm, side =2.0 cm, bottom=2.4026 cm, cone to radius=1cm, Winston cone to radius=0.6cm (GlueX-doc-1077), efficiency=81%.
    • Preliminary results for collection efficiency for trapezoidal light guides (inner outside top geometry) with air gap:
    • Intput: top = 2.525 cm, side =2.0 cm, bottom=2.4026 cm, length = 8 cm
    • output: 1.2cm x 1.2 cm square
    • Ratio of input/output areas = 0.29
    • 1 mm lucite transition piece: efficiency = 87%.
    • 1 mm air gap, efficiency = 45%.