* Very low cross-talk and noise. | * Very low cross-talk and noise. | ||
* Will have 5 for Hall B and 2 for Hall D fairly soon for testing. | * Will have 5 for Hall B and 2 for Hall D fairly soon for testing. | ||
− | * See Ben's | + | * See Ben's slides for many more details. |
− | ''' | + | '''JANA Remote Control''' |
+ | |||
+ | Dave described a new remote control feature for JANA processes. | ||
+ | |||
+ | * Framework for controlling monitoring and level 3 farms, also useful for control/monitoring of offline farm jobs. | ||
+ | * Based on cMsg (same as ROOTSpy). | ||
+ | * Uses very simple subject/type/text conventions for message routing and response. | ||
+ | * Still need to extend the JANA control language and allow for user customization. | ||
+ | * Should allow easy integration with DAQ system via use of a farm manager CODA component. | ||
+ | * JANA processes would not be CODA components, just the farm manager. | ||
+ | * Farm manager will probably have to be developed by Hall D as DAQ group thinks it is too experiment-specific. | ||
+ | * Could use AFECS to control farm processes, not clear if this would be an advantage. | ||
+ | * Farm processes will get events from the ET system, control is via cMsg system. | ||
+ | * See Dave's slides for many more details. | ||
+ | |||
+ | |||
+ | '''Online Event Display''' |
Revision as of 10:07, 8 January 2010
Contents
Agenda
- Announcements
- Review of minutes from 8-Dec-2009 meeting
- Hall B discriminator - Ben
- JANA remote monitoring/control facility PDF - David L
- deferred to next meeting - BNL NSLS-II PLC evaluation (full vsn) (summary)- Elliott
- deferred to next meeting - PLC control system - Elliott
- Allen-Bradley Point I/O for RS232 communication
- Common Industrial Protocol (CIP) over Ethernet/IP vs over ControlNet, copper vs fiber
- Direct EPICS to Ethernet/IP communications
- Web access using 1756-EWEB module
- XML program storage
- Alarming, paging, email
- Java online event display based on Dave Heddle's framework, HDDM and EVIO.
- Coil test update - Elliott
- Other electronics and trigger status reports - Fernando, Chris, Ben, Ed, Alex, Dave
Time/Location
1:30 PM Wed 6-Jan-2010 CC F326
Announcements
Next Meeting
1:30 PM Wed 20-Jan-2010
New Action Items from this Meeting
Minutes
Attendees: Elliott W, Beni Z, Simon T, Ben R, Fernando B, Alex S, Lubomir P, Carl T, Vardan G, Pedro Toledo.
Hall B Discriminator
Ben described recent work on a discriminator developed for Hall B. Fernando says it fits Hall D needs perfectly, and is much cheaper and better than the CAEN V895 discriminators we were planning to use.
- 16-channel dual-threshold, non-updating, 0 -> -1V.
- Includes many scalers.
- Standard VME mount.
- Very similar to CAEN V895 but about one half the cost.
- 200 needed for CLAS12, about 200 for Hall D.
- Very low cross-talk and noise.
- Will have 5 for Hall B and 2 for Hall D fairly soon for testing.
- See Ben's slides for many more details.
JANA Remote Control
Dave described a new remote control feature for JANA processes.
- Framework for controlling monitoring and level 3 farms, also useful for control/monitoring of offline farm jobs.
- Based on cMsg (same as ROOTSpy).
- Uses very simple subject/type/text conventions for message routing and response.
- Still need to extend the JANA control language and allow for user customization.
- Should allow easy integration with DAQ system via use of a farm manager CODA component.
- JANA processes would not be CODA components, just the farm manager.
- Farm manager will probably have to be developed by Hall D as DAQ group thinks it is too experiment-specific.
- Could use AFECS to control farm processes, not clear if this would be an advantage.
- Farm processes will get events from the ET system, control is via cMsg system.
- See Dave's slides for many more details.