== Preliminary Calorimeter Layout == | == Preliminary Calorimeter Layout == | ||
<gallery> | <gallery> | ||
− | Image:fcal2_vxs_crates.png | Fig. 1 Connection of the FCAL2 insert modules to readout (VXS) crates | + | <!-- Image:fcal2_vxs_crates.png | Fig. 1 Connection of the FCAL2 insert modules to readout (VXS) crates --> |
+ | Image:fcal2_vxs_crates_new.png | Fig. 1 Connection of the FCAL2 insert modules to readout (VXS) crates | ||
Image:fcal2_crates1.png | Fig. 2 Location of the FCAL2 crates in four racks | Image:fcal2_crates1.png | Fig. 2 Location of the FCAL2 crates in four racks | ||
</gallery> | </gallery> | ||
Line 13: | Line 14: | ||
** D1-2-BOT: 224 channels connected to 14 fadcs | ** D1-2-BOT: 224 channels connected to 14 fadcs | ||
** D1-3-TOP: 252 channels connected to 16 fadcs | ** D1-3-TOP: 252 channels connected to 16 fadcs | ||
+ | |||
+ | [https://halldweb.jlab.org/detectors/fcal2/cables/signal/translation_ecal_fadc.xlsx Translation table] | ||
* '''Wiener crate (LV, MPOD)''' | * '''Wiener crate (LV, MPOD)''' | ||
Line 18: | Line 21: | ||
* '''HV crates''' | * '''HV crates''' | ||
− | ** D1-4-TOP: | + | ** D1-4-TOP: 10 CAEN modules (48 channels in each) |
− | ** D1-4-MID: | + | ** D1-4-MID: 10 CAEN modules |
− | ** D1-4-BOT: | + | ** D1-4-BOT: 16 CAEN modules |
+ | ** [https://halldweb.jlab.org/detectors/fcal2/cables/hv_distribution/translation_ecal_hv_ver3.xlsx Translation table] | ||
+ | ** [https://halldweb.jlab.org/detectors/fcal2/cables/hv_distribution/hv_distribution_ver3.xlsx HV distribution ] | ||
+ | * [[ECAL Controllers and VTPs]] | ||
− | * Total width of four racks: 127 | + | |
+ | |||
+ | * Total width of four racks: 127 inches | ||
+ | |||
+ | * Possible location of racks in Hall D | ||
+ | <gallery> | ||
+ | Image:racks_in_halld.jpg | Fig. 1 Possible location of 4 racks | ||
+ | </gallery> |
Latest revision as of 10:47, 20 March 2025
Preliminary Calorimeter Layout
- VXS readout crates
- D1-1-TOP: 224 channels connected to 14 fadcs
- D1-1-MID: 224 channels connected to 14 fadcs
- D1-1-BOT: 224 channels connected to 14 fadcs
- D1-2-TOP: 224 channels connected to 14 fadcs
- D1-2-MID: 224 channels connected to 14 fadcs
- D1-2-BOT: 224 channels connected to 14 fadcs
- D1-3-TOP: 252 channels connected to 16 fadcs
- Wiener crate (LV, MPOD)
- D1-3-BOT: 2 MPOD modules
- HV crates
- D1-4-TOP: 10 CAEN modules (48 channels in each)
- D1-4-MID: 10 CAEN modules
- D1-4-BOT: 16 CAEN modules
- Translation table
- HV distribution
- Total width of four racks: 127 inches
- Possible location of racks in Hall D