Difference between revisions of "Cables and Crates"

From GlueXWiki
Jump to: navigation, search
(Possible rearranging of cables)
(Possible rearranging of cables)
 
(5 intermediate revisions by the same user not shown)
Line 30: Line 30:
 
== Possible rearranging of cables  ==
 
== Possible rearranging of cables  ==
  
* Move 108 channels in the rocfcal2 (rocfcal8)  crate connected to the insert to the rocfcal5 (rocfcal11) crate. The total number of channels in this crate: 108 + 108 = 216 (connect to 14 FADCs), see Fig. 1
+
* Move 108 channels from the rocfcal2 (rocfcal8)  crate connected to the insert to the rocfcal5 (rocfcal11) crate. The total number of channels in this crate: 108 + 108 = 216 (connect to 14 FADCs), see Fig. 1
* Move 126 channels in the rocfcal5 (rocfcal11)  crate connected to the insert to the rocfcal2 (rocfcal8) crate. The total number of channels in this crate: 130 (remaining) + 126 = 256 (connect to 16 FADCs). Connect 4 remaining cables to other crates
+
* Move 126 channels in the rocfcal5 (rocfcal11)  crate connected to the insert to the rocfcal2 (rocfcal8) crate. The total number of channels in this crate: 130 (remaining) + 126 = 256 (connect to 16 FADCs), see Fig. 2. Connect 4 remaining cables to other crates, see Fig. 3
 +
 
 +
<gallery>
 +
Image:rocfcal5_new_cables.png | Fig. 1 rocfcal5 crate after re-cabling (216 channels, connected to all FCAL insert modules)
 +
Image:rocfcal2_new_cables.png | Fig. 2 rocfcal2 crate after re-cabling (256 channels, connected to all lead glass modules)
 +
Image:rocfcal4_adc.png | Fig. 3 rocfcal4 connect 4 lead glass channels to the new flash in Slot 19
 +
 
 +
</gallery>

Latest revision as of 16:42, 26 October 2022

Calorimeter Layout

VXS crate layout

VXS crates connected to the FCAL2 insert region

  • Blue region corresponds to ADC channels connected to the FCAL2 insert region (21x21 lead glass modules). Yellow boxes correspond to channels connected to the region outside the insert.
  • 108 ADC channels in each of four crates are connected to the insert region
  • 238 ADC channels are used in each crate

Possible rearranging of cables

  • Move 108 channels from the rocfcal2 (rocfcal8) crate connected to the insert to the rocfcal5 (rocfcal11) crate. The total number of channels in this crate: 108 + 108 = 216 (connect to 14 FADCs), see Fig. 1
  • Move 126 channels in the rocfcal5 (rocfcal11) crate connected to the insert to the rocfcal2 (rocfcal8) crate. The total number of channels in this crate: 130 (remaining) + 126 = 256 (connect to 16 FADCs), see Fig. 2. Connect 4 remaining cables to other crates, see Fig. 3