− | Step 5. Remove aluminized mylar wrapped around the glass block. Note, the Al Mylar thickness is about 13 um; the Mylar joint is positioned under the strap (no sticky tape is used) | + | Step 5. Remove aluminized mylar wrapped around the glass block. Note, the Al Mylar thickness is about 13 um; the Mylar joint is positioned under the strap (no sticky tape is used on the joint) |
Latest revision as of 22:54, 17 October 2022
Disassemble Lead Glass Module
Step 1: Inspect lead glass module (see corresponding section) to make sure the the module
has to be disassembled.
Step 2. Loose screws on the flange attached to the PMT housing
Step 3. Remove steel strap assembly holding together the PMT housing and lead glass block
Step 4. Remove silicon cookie (note the cookie may stick to the glass block; use a wood stick to scrub if needed)
Step 5. Remove aluminized mylar wrapped around the glass block. Note, the Al Mylar thickness is about 13 um; the Mylar joint is positioned under the strap (no sticky tape is used on the joint)