Difference between revisions of "SRC/CT Detector Calibration"
From GlueXWiki
Line 27: | Line 27: | ||
! Version !! Date !! Files per run !! Compared with last version | ! Version !! Date !! Files per run !! Compared with last version | ||
|- | |- | ||
− | | 00 || online monitoring || a few percent of all data || | + | | 00 || online monitoring || a few percent of all data || created online by RootSpy |
|- | |- | ||
− | | 01 || shortly after each run || 5 || | + | | 01 || shortly after each run || 5 || first launch |
|- | |- | ||
− | | 02 || 01/07/2022 || 40 || | + | | 02 || 01/07/2022 || 40 || various calibration updates |
|- | |- | ||
− | | 03 || 02/14/2022 || 5 || | + | | 03 || 02/14/2022 || 5 || various calibration updates |
|- | |- | ||
− | | 04 || 03/14/2022 || 5 || | + | | 04 || 03/14/2022 || 5 || various calibration updates |
|- | |- | ||
− | | 05 || 04/22/2022 || 40 (90271-90378), 5 (rest) || | + | | 05 || 04/22/2022 || 40 (90271-90378), 5 (rest) || various calibration updates |
|- | |- | ||
| 06 || 07/03/2022 || 2 || BCAL calibrations added, photon beam endpoint energy added | | 06 || 07/03/2022 || 2 || BCAL calibrations added, photon beam endpoint energy added |
Revision as of 10:42, 2 August 2022
Overview of subdetectors
Detector | Tasks | Calibration expert |
---|---|---|
CDC | gains, dE/dx, time-to-distance | Simon Taylor |
FDC | timing, wire plane, pedestals, gain/energy non-linearities | Keigo Mizutani |
BCAL | timing, z-position, gain ratios, gains, non-linearities | Mark Dalton, Karthik Suresh |
FCAL | gains/non-linearities/timing | Igal Jaegle |
TOF | timing offsets, timewalk, attenuation, gain | Beni Zihlmann |
ST | timing, resolution | Sean Dobbs |
TAGH | timing offsets, timewalk | Alex Somov |
TAGM | timing offsets, timewalk | Alex Somov |
PS | timing offsets, timewalk | Alex Somov |
Monitoring launches
Version | Date | Files per run | Compared with last version |
---|---|---|---|
00 | online monitoring | a few percent of all data | created online by RootSpy |
01 | shortly after each run | 5 | first launch |
02 | 01/07/2022 | 40 | various calibration updates |
03 | 02/14/2022 | 5 | various calibration updates |
04 | 03/14/2022 | 5 | various calibration updates |
05 | 04/22/2022 | 40 (90271-90378), 5 (rest) | various calibration updates |
06 | 07/03/2022 | 2 | BCAL calibrations added, photon beam endpoint energy added |
07 | 07/27/2022 | 2 | Photon beam endpoint energy corrected, TAGH calibrations of Compton runs added |
- Calibration check spreadsheets:
- Location of output files:
- monitoring histograms, REST files, standalone files specific to some sub-detectors: /cache/halld/offline_monitoring/RunPeriod-2021-11/verXX
- merged histogram files: /work/halld/data_monitoring/RunPeriod-2021-11/mon_verXX/rootfiles/
Data quality issues
- Some hardware or software issues can not be fixed by calibrations. Attention is needed during the data analysis
Subdetector | Issue | Runs affected | Actions required |
---|---|---|---|
CDC | TBA | TBA | TBA |
TAGH | channel 1-16 has two peaks of hits | all runs | TBD |
TAGM | channel 100 has very low occupancy | all runs | TBD |