Difference between revisions of "RunPeriod-2021-09 Validation"
From GlueXWiki
(→Runs 81113 - 81267) |
(→Batch 1) |
||
Line 188: | Line 188: | ||
== Batch 1 == | == Batch 1 == | ||
''' Runs 81113 - 81267 ''' | ''' Runs 81113 - 81267 ''' | ||
+ | |||
'''Detector systems used are FCAL,TAGM,TAGH,CCAL,BCAL,PS. No Magnetic field. SC, CDC, FDC were not used ''' | '''Detector systems used are FCAL,TAGM,TAGH,CCAL,BCAL,PS. No Magnetic field. SC, CDC, FDC were not used ''' | ||
+ | |||
* [https://halldweb.jlab.org/data_monitoring/Plot_Browser.html Plot Browser] | * [https://halldweb.jlab.org/data_monitoring/Plot_Browser.html Plot Browser] | ||
* [https://halldweb.jlab.org/wiki/index.php/Offline_Monitoring_Data_Validation Reference Plots] | * [https://halldweb.jlab.org/wiki/index.php/Offline_Monitoring_Data_Validation Reference Plots] |
Revision as of 12:41, 1 October 2021
Contents
Monitoring Team
Sasha: PS
Tyler: Tagger
Igal: FCAL
Drew: CCAL
Run list
Note on monitoring launches
PS Calibration
Tagger Calibration
FCAL Calibration
- Blue LED 100Hz continuous 15V
- HV set to 1500V -> 80280
- HV set to 1550V -> 80284
- HV set to 1600V -> 80285
- HV set to 1650V -> 80286
- HV set to 1700V -> 80287
- HV set to 1750V -> 80288
- HV set to 1800V -> 80289
- Blue LED 100Hz continuous 10V
- HV set to 1800V -> 80290
- HV set to 1750V -> 80292
- HV set to 1700V -> 80293
- HV set to 1650V -> 80294
- HV set to 1600V -> 80295
- HV set to 1550V -> 80296
- HV set to 1500V -> 80297
CCAL Calibration
2021 Run List
Run Lists
AMO | 81113,81114,81118,81119,81120,81126,81127,81128,81129,81130,81131,81132,81133,81134,81159,81164,81221,81222,81223,81261,81262,81263,81264,81265,81266,81267 |
Monitoring Launch Checks
Team members
- BCAL: Tolga Erbora, Zisis Papandreou/Regina
- CDC: Naomi Jarvis/CMU, Jason Barlow
- FCAL: Susan Schadmand
- FDC: Churamani Paudel
- PS/PSC: Kevin Luckas
- TAGH/TAGM: Gabriel Rodriguez
- TOF: Edmundo Barriga
- SC: Rupesh Dotel
- Timing: Mariana Khachatryan
- Analysis: Lawrence Ng
Detector/Calibration Experts
- BCAL: Mark Dalton, Zisis Papandreou, Elton Smith
- CDC: Naomi Jarvis, Beni Zihlmann
- FCAL: Colin Gleason, Matt Shepherd
- FDC: Lubomir Pentchev
- PS/PSC: Alex Somov, Olga Cortes
- TAGH: Alex Somov, Olga Cortes
- TAGM: Richard Jones
- TOF: Paul Eugenio, Beni Zhilmann
- SC: Mark Ito
- Timing: Sean Dobbs
- Analysis: Alexander Austregesilo, Sean Dobbs
Batch 1
Runs 81113 - 81267
Detector systems used are FCAL,TAGM,TAGH,CCAL,BCAL,PS. No Magnetic field. SC, CDC, FDC were not used
- Plot Browser
- Reference Plots
- Monitoring Spreadsheets