== TOF I ==
 +
 
* WBS 1.5.2.3.1
 
* WBS 1.5.2.3.1
  
Line 12: Line 14:
 
** standard: 2.54 x 6.00 x 252.00
 
** standard: 2.54 x 6.00 x 252.00
 
** half-width: 2.54 x 3.00 x 252.00
 
** half-width: 2.54 x 3.00 x 252.00
** half-length: 2.54 x 6.00 x 120
+
** half-length (full-width): 2.54 x 6.00 x 120
 
* count per layer
 
* count per layer
 
** standard modules: 38
 
** standard modules: 38
Line 31: Line 33:
 
** PMT count for these = 2×(8 + 8) + 8 = 40
 
** PMT count for these = 2×(8 + 8) + 8 = 40
 
** Standard PMT count would be 176 - 40 = 136
 
** Standard PMT count would be 176 - 40 = 136
 +
 +
== TOF II ==
 +
 +
* number of layers: 2
 +
** horizontal and vertical orientation
 +
* if no special modules, would be 42 counters per layer
 +
* special modules take up 8 standard module spaces per layer
 +
** two standard spaces: half-width modules
 +
** three standard spaces: three-quarter-width modules
 +
** three standard spaces: half-length modules
 +
* dimensions (centimeters)
 +
** standard: 2.54 x 6.00 x 252.00
 +
** three-quarter-width: 2.54 x 4.50 x 252.00
 +
** half-width: 2.54 x 3.00 x 252.00
 +
** half-length (three-quarter-width): 2.54 x 4.50 x 117.00
 +
* count per layer
 +
** standard modules: 34
 +
** three-quarter-width modules: 4
 +
** half-width modules: 4
 +
** half-length modules: 8
 +
* totals (both layers)
 +
** standard modules: 68 (&Delta = −8)
 +
** three-quarter-width modules: 8 (&Delta = +8)
 +
** half-width modules: 8 (&Delta = 0)
 +
** half-length (full-width) modules: 0 (&Delta = −8)
 +
** half-length (three-quarter-width) modules: 16 (&Delta = +16)
 +
** sum of all modules: 100 (&Delta = +8)
 +
* PMT's
 +
** all modules have two PMT's except half-length modules which have one
 +
** count is 2×(100-16) + 16 = 184

Revision as of 13:33, 28 June 2019

TOF I

  • WBS 1.5.2.3.1

Tof.png

  • number of layers: 2
    • horizontal and vertical orientation
  • if no special modules, would be 42 counters per layer
  • special modules take up 4 standard module spaces per layer
    • two standard spaces: half-width modules
    • two standard spaces: half-length modules
  • dimensions (centimeters)
    • standard: 2.54 x 6.00 x 252.00
    • half-width: 2.54 x 3.00 x 252.00
    • half-length (full-width): 2.54 x 6.00 x 120
  • count per layer
    • standard modules: 38
    • half-width modules: 4
    • half-length modules: 4
  • totals (both layers)
    • standard modules: 76
    • half-width modules: 8
    • half-length modules: 8
    • sum of all modules: 92
  • PMT's
    • all modules have two PMT's except half-length modules which have one
    • count is 2×(92-8) + 8 = 176
  • high rate counters
    • inner two standard counters on both sides, both layers = 8
    • all of the half-width counters = 8
    • all of the half-length counters = 8
    • PMT count for these = 2×(8 + 8) + 8 = 40
    • Standard PMT count would be 176 - 40 = 136

TOF II

  • number of layers: 2
    • horizontal and vertical orientation
  • if no special modules, would be 42 counters per layer
  • special modules take up 8 standard module spaces per layer
    • two standard spaces: half-width modules
    • three standard spaces: three-quarter-width modules
    • three standard spaces: half-length modules
  • dimensions (centimeters)
    • standard: 2.54 x 6.00 x 252.00
    • three-quarter-width: 2.54 x 4.50 x 252.00
    • half-width: 2.54 x 3.00 x 252.00
    • half-length (three-quarter-width): 2.54 x 4.50 x 117.00
  • count per layer
    • standard modules: 34
    • three-quarter-width modules: 4
    • half-width modules: 4
    • half-length modules: 8
  • totals (both layers)
    • standard modules: 68 (&Delta = −8)
    • three-quarter-width modules: 8 (&Delta = +8)
    • half-width modules: 8 (&Delta = 0)
    • half-length (full-width) modules: 0 (&Delta = −8)
    • half-length (three-quarter-width) modules: 16 (&Delta = +16)
    • sum of all modules: 100 (&Delta = +8)
  • PMT's
    • all modules have two PMT's except half-length modules which have one
    • count is 2×(100-16) + 16 = 184