| Date || Time || Current, A || Ramp, A/s || PXI file || LOG || Cause  
+
|-
 +
| Date || Time || Current, A || Ramp, A/s || PXI file || LOG || Coil 2 spike? || Cause  
 
|-  
 
|-  
| 2016/02/07 || 17:08:30 || 890 || 0.12 || pxi_20160207_170730.root || [https://logbooks.jlab.org/entry/3376642 log ] || Not QD
+
| 2016/04/05 || 13:44:16 || 1200 || 0. || pxi_20160405_133835.root || [https://logbooks.jlab.org/entry/3395527 log ] || after
 +
  | Refrigerator trip
 +
|-
 +
| 2016/03/28 || 09:03:29 || 508 || 0.2 || pxi_20160328_090140.root || [https://logbooks.jlab.org/entry/3392805 log ] || after
 +
  | QD was triggered (marginally) by a 2s-long negative voltage excursion on Coil 2. A spike followed 0.15s after the dump.   
 +
|-
 +
| 2016/03/23 || 12:49:29 || 800 || 0. || pxi_20160323_124313.root || [https://logbooks.jlab.org/entry/3391874 log ] || no
 +
  | lead flow transient 
 +
|-
 +
| 2016/02/12 || 09:45:59 || 300 || 0. ||  || [https://logbooks.jlab.org/entry/3378500 log ] || not checked
 +
  | Slow dump (cause uncertain) triggered QD and fast dump 
 +
|-
 +
| 2016/02/07 || 17:08:30 || 890 || 0.12 || pxi_20160207_170730.root || [https://logbooks.jlab.org/entry/3376642 log ] || after
 +
  | Slow dump (cause uncertain) triggered QD and fast dump 
 +
|-
 +
| 2016/02/07 || 14:38:25 || 1000 || 0. || pxi_20160207_142631.root || [https://logbooks.jlab.org/entry/3376541 log ] || no
 +
  | Slow dump (cause uncertain) triggered QD and fast dump 
 
|}
 
|}

Revision as of 02:19, 1 February 2017

Unintended current dumps

The list is in the reverse chronological order. It does not include very early times.

Date Time Current, A Ramp, A/s PXI file LOG Coil 2 spike? Cause
2016/04/05 13:44:16 1200 0. pxi_20160405_133835.root log after Refrigerator trip
2016/03/28 09:03:29 508 0.2 pxi_20160328_090140.root log after QD was triggered (marginally) by a 2s-long negative voltage excursion on Coil 2. A spike followed 0.15s after the dump.
2016/03/23 12:49:29 800 0. pxi_20160323_124313.root log no lead flow transient
2016/02/12 09:45:59 300 0. log not checked Slow dump (cause uncertain) triggered QD and fast dump
2016/02/07 17:08:30 890 0.12 pxi_20160207_170730.root log after Slow dump (cause uncertain) triggered QD and fast dump
2016/02/07 14:38:25 1000 0. pxi_20160207_142631.root log no Slow dump (cause uncertain) triggered QD and fast dump