Bad CAEN TDCs start at 22028 ??
  
 
{| class="wikitable"
 
{| class="wikitable"
Line 119: Line 121:
 
| 22054  ||  || PARA  
 
| 22054  ||  || PARA  
 
|-
 
|-
| 22055  || || PARA  
+
| 22055  || x || PARA, bad F1TDC
 
|-
 
|-
 
| 22056  ||  || PERP (PPAP)
 
| 22056  ||  || PERP (PPAP)
 
|-
 
|-
| 22057  || || AMO
+
| 22057  || x || AMO, bad F1TDC
 
|-
 
|-
| 22058  || || AMO
+
| 22058  || x || AMO, bad F1TDC
 
|-
 
|-
| 22060  || x | PERP, short run|, intensity scan
+
| 22060  || x || PERP, short run|, intensity scan
 
|-
 
|-
 
| 22077  || x || PERP, short run, trigger studies
 
| 22077  || x || PERP, short run, trigger studies

Revision as of 23:54, 20 December 2016

Problems/Features

New f250 firmware is new. Seems so good so far.

TOF TDC shift is shifting, keep an eye on it.

Notes

Bad CAEN TDCs start at 22028 ??
Run Is Good? Notes
21941 x Lost, long mode calibration data
21942 production mode calibration data
21943 x production mode calibration data, some bad F1TDCs
21944 x Lost, production, TAGH scan
21945 production, TAGH scan
21946 CDC, TOF, TAGH voltage scan
21947 x Lost, CDC, TOF, TAGH voltage scan
21948 CDC, TOF, TAGH voltage scan
21949 CDC, TOF, TAGH voltage scan
21950 x Lost, CDC, TOF, TAGH voltage scan
21951 CDC, TOF, TAGH voltage scan
21952 CDC, TOF, TAGH voltage scan
21954 x short, bad?
21955 x short, bad?
21956 PS magnet scan
21957 PS magnet scan
21958 x PS magnet scan, short
21961 x PS magnet scan, short
21962 PS magnet scan
21963 x PS magnet scan, some bad F1TDCs
21964 PS magnet scan
21968 G long mode, production
21969 PERP
21971 PERP
21972 TOF, CDC voltage scan, PERP, some bad F1TDCs
21973 x TOF, CDC voltage scan, PERP, some bad F1TDCs
21974 x TOF, CDC voltage scan, PERP, some bad F1TDCs
21975 x TOF, CDC voltage scan, PERP, some bad F1TDCs
21976 x TOF, CDC voltage scan, PERP, some bad F1TDCs
21977 TOF, CDC voltage scan, PERP
21978 x TOF, CDC voltage scan, PERP, some bad F1TDCs
21981 PARA
22001 trigger studies???
22002 trigger studies???
22014 x PARA, bad F1TDCs
22015 x PARA, bad F1TDCs
22016 PARA
22017 x PERP, bad F1TDCs
22018 PERP
22019 x PERP, bad F1TDCs
22020 PERP
22021 x AMO, bad F1TDCs
22022 x PARA, bad F1TDCs
22023 x PARA, bad F1TDCs
22025 x PERP, bad F1TDCs
22026  ? PERP, 1 file, going to ignore
22027  ? PERP, trigger studies?
22033 x Trigger/DAQ studies
22035 x Trigger/DAQ studies
22036 x Trigger/DAQ studies
22038 x Trigger/DAQ studies
22052 PARA
22053 PARA
22054 PARA
22055 x PARA, bad F1TDC
22056 PERP (PPAP)
22057 x AMO, bad F1TDC
22058 x AMO, bad F1TDC
22060 x , intensity scan
22077 x PERP, short run, trigger studies
22080 x PERP, short run , trigger studies
22082 x PERP, short run , trigger studies
22083 x PERP, short run , trigger studies
22084 x PERP, short run , trigger studies
22102 x PERP, short run , trigger studies
22103 x PERP, short run , trigger studies
22104 x PERP, short run , trigger studies
22105 x PERP, short run , trigger studies
22106 x PERP, short run , trigger studies
22111 x PERP, short run , trigger studies
22146  ? DAQ test run, PARA
22155 x trigger studies
22158 x trigger studies