| 21942 ||  || production mode calibration data
 
| 21942 ||  || production mode calibration data
 
|-
 
|-
| 21943 ||   || production mode calibration data
+
| 21943 || x || production mode calibration data, some bad F1TDCs
 
|-
 
|-
 
| 21944 ||  x || Lost, production, TAGH scan
 
| 21944 ||  x || Lost, production, TAGH scan
Line 42: Line 42:
 
|-
 
|-
 
| 21957 ||  || PS magnet scan
 
| 21957 ||  || PS magnet scan
 +
|-
 +
| 21958 || x || PS magnet scan, short
 +
|-
 +
| 21961 || x || PS magnet scan, short
 
|-
 
|-
 
| 21962 ||  || PS magnet scan
 
| 21962 ||  || PS magnet scan
 
|-
 
|-
| 21963 || || PS magnet scan
+
| 21963 || x || PS magnet scan, some bad F1TDCs
 
|-
 
|-
 
| 21964 ||  || PS magnet scan
 
| 21964 ||  || PS magnet scan
Line 55: Line 59:
 
| 21971 ||  ||  PERP
 
| 21971 ||  ||  PERP
 
|-
 
|-
| 21972 ||  || TOF, CDC voltage scan, PERP
+
| 21972 ||  || TOF, CDC voltage scan, PERP, some bad F1TDCs
 
|-
 
|-
| 21973 ||  || TOF, CDC voltage scan, PERP
+
| 21973 ||x || TOF, CDC voltage scan, PERP, some bad F1TDCs
 
|-
 
|-
| 21974 || || TOF, CDC voltage scan, PERP
+
| 21974 || x || TOF, CDC voltage scan, PERP, some bad F1TDCs
 
|-
 
|-
| 21975 ||  || TOF, CDC voltage scan, PERP
+
| 21975 ||x || TOF, CDC voltage scan, PERP, some bad F1TDCs
 
|-
 
|-
| 21976 || || TOF, CDC voltage scan, PERP
+
| 21976 || x || TOF, CDC voltage scan, PERP, some bad F1TDCs
 
|-
 
|-
 
| 21977 ||  || TOF, CDC voltage scan, PERP
 
| 21977 ||  || TOF, CDC voltage scan, PERP
 
|-
 
|-
| 21978 || || TOF, CDC voltage scan, PERP
+
| 21978 || x || TOF, CDC voltage scan, PERP, some bad F1TDCs
 
|-
 
|-
 
| 21981 ||  || PARA
 
| 21981 ||  || PARA
 
  |}
 
  |}

Revision as of 20:55, 17 December 2016

Problems/Features

New f250 firmware is new. Seems so good so far.

TOF TDC shift is shifting, keep an eye on it.

Notes

Run Is Good? Notes
21941 x Lost, long mode calibration data
21942 production mode calibration data
21943 x production mode calibration data, some bad F1TDCs
21944 x Lost, production, TAGH scan
21945 production, TAGH scan
21946 CDC, TOF, TAGH voltage scan
21947 x Lost, CDC, TOF, TAGH voltage scan
21948 CDC, TOF, TAGH voltage scan
21949 CDC, TOF, TAGH voltage scan
21950 x Lost, CDC, TOF, TAGH voltage scan
21951 CDC, TOF, TAGH voltage scan
21952 CDC, TOF, TAGH voltage scan
21954 x short, bad?
21955 x short, bad?
21956 PS magnet scan
21957 PS magnet scan
21958 x PS magnet scan, short
21961 x PS magnet scan, short
21962 PS magnet scan
21963 x PS magnet scan, some bad F1TDCs
21964 PS magnet scan
21968 G long mode, production
21969 PERP
21971 PERP
21972 TOF, CDC voltage scan, PERP, some bad F1TDCs
21973 x TOF, CDC voltage scan, PERP, some bad F1TDCs
21974 x TOF, CDC voltage scan, PERP, some bad F1TDCs
21975 x TOF, CDC voltage scan, PERP, some bad F1TDCs
21976 x TOF, CDC voltage scan, PERP, some bad F1TDCs
21977 TOF, CDC voltage scan, PERP
21978 x TOF, CDC voltage scan, PERP, some bad F1TDCs
21981 PARA