Difference between revisions of "PrimEx-eta phase3 FCAL time/energy calibrations"

From GlueXWiki
Jump to: navigation, search
(Periods)
(Periods)
Line 18: Line 18:
 
* period 4: 110585-110599 (Be target - B-field ramping down)
 
* period 4: 110585-110599 (Be target - B-field ramping down)
 
* period 5: 110600-110621 (Be target - B-field OFF)
 
* period 5: 110600-110621 (Be target - B-field OFF)
* period 6: 110638-110640 (He target cooling - B-field ramping up)
+
* period 6: 110637-110640 (He target cooling - B-field ramping up, FCAL HV change)
 
* period 7: 110641-110672 (He target w/ B-field)
 
* period 7: 110641-110672 (He target w/ B-field)
 
* period 8: 110675-?????? (He target w/ B-field/new trigger)
 
* period 8: 110675-?????? (He target w/ B-field/new trigger)

Revision as of 14:59, 9 September 2022

List of changes

These lists are giving the run ranges where the FCAL hardware was not changed.

Monitoring results

What is currently in the default variation

Periods

The periods in BOLD are calibrated i.e. have a pedestal and gain tables. Each period corresponds to constant FCAL and/or experimental conditions.

  • period 0: (empty Be target)
  • period 1: (empty Be target)
  • period 2: 110498-110549 (Be target - B-field ON)
  • Period 3: 110553-110583 (Be target - B-field ON, FCAL HV change)
  • period 4: 110585-110599 (Be target - B-field ramping down)
  • period 5: 110600-110621 (Be target - B-field OFF)
  • period 6: 110637-110640 (He target cooling - B-field ramping up, FCAL HV change)
  • period 7: 110641-110672 (He target w/ B-field)
  • period 8: 110675-?????? (He target w/ B-field/new trigger)

Gain matching calibration plots

Checking the FCAL gains

Energy dependence correction monitoring plots

Timing calibration

Bad block map

This map is done for each run number by combining the info collected by analysing the LED and pi0 skims.