List of changes

These lists are giving the run ranges where the FCAL hardware was not changed.

Monitoring results

The monitoring results can be found here: [1]

Periods

All periods listed here are calibrated on the default variation

  • period 1, 81113 -> 81120, 150 nA, Summer 2020 HV, FCAL pi0 with FDC & CDC turn off
  • period 2, 81126 -> 81164, 150 nA, Summer 2020 HV - 6V, FCAL pi0 with FDC & CDC turn off
  • period 3, 81221 -> 81123, 150 nA, Fall 2021 ver 1, FCAL pi0 with FDC & CDC turn off
  • period 4, 81262 -> 81267, 200 nA, Fall 2021 ver 2, FCAL pi0 with FDC & CDC turn off
  • period 5, 81331 -> 81342, 50 nA, Fall 2021 ver 2, low intensity Be production with FDC & CDC turn on
  • period 6, 81343 -> 81355, 50 nA, Fall 2021 ver 2, low intensity Be production with FDC & CDC turn on
  • period 7, 81356 -> 81373, 100 nA, Fall 2021 ver 2, medium intensity Be production with FDC & CDC turn off
  • period 8, 81374 -> 81381, 200 nA, Fall 2021 ver 2, Be production with FDC & CDC turn off
  • period 14, 81411 -> 81430, 200 nA, Fall 2021 ver 2, He cell full with FDC & CDC turn off (cal. to be done for FCAL)
  • period 15, 81431 -> 81444, 100 nA, Fall 2021 ver 3, He cell full with FDC & CDC turn off (cal. to be done for FCAL)
  • period 16, 81445 -> 81 81470, 200 nA, Fall 2021 ver 3, He cell full with FDC & CDC turn off
  • period 17, 81472 -> 81520, 200 nA, Fall 2021 ver 3, B-field, He cell full with FDC & CDC turn on
  • period 18, 81521 -> 81531, 200 nA, Fall 2021 ver 3, B-field, He cell full with FDC & CDC turn on
  • period 20, 81564 -> 81589, 200 nA, Fall 2021 ver 3, B-field, He cell full with FDC & CDC turn on
  • period 21, 81590 -> 81595, 200 nA, Fall 2021 ver 3, B-field, He cell full with FDC & CDC turn on
  • period 22, 81597 -> 81613, 200 nA, Fall 2021 ver 3, B-field, He cell full with FDC & CDC turn on
  • period 23, 81614 -> 81633, 200 nA, Fall 2021 ver 3, B-field, He cell full with FDC & CDC turn on
  • period 25, 81675 -> 81681, 200 nA, Fall 2021 ver 3, B-field, He cell full with FDC & CDC turn on
  • period 26, 81682 -> 81696, 200 nA, Fall 2021 ver 3, B-field, He cell full with FDC & CDC turn on
  • period 27, 81704 -> 81711, 200 nA, Fall 2021 ver 3, B-field, He cell full with FDC & CDC turn on
  • period 28, 81712 -> 81999, 200 nA, Fall 2021 ver 3, B-field, He cell full with FDC & CDC turn on
  • Periods calibrated for data analysis
    • period 5 / run range: 81331-81342 / number of runs:12
    • period 6 / run range: 81343-81353 / number of runs:11
    • period 7 / run range: 81356-81372 / number of runs:10
    • period 8 / run range: 81374-81378 / number of runs:5
    • period 14 / run range: 81411-81430 / number of runs:17
    • period 15 / run range: 81431-81444 / number of runs:14
    • period 16 / run range: 81445-81453 / number of runs:9
    • period 17 / run range: 81472-81490 / number of runs:18
    • period 18 / run range: 81524-81530 / number of runs:7
    • period 20 / run range: 81564-81572 / number of runs:7
    • period 21 / run range: 81590-81595 / number of runs:6
    • period 22 / run range: 81597-81606 / number of runs:10
    • period 23 / run range: 81614-81630 / number of runs:15
    • period 25 / run range: 81675-81681 / number of runs:6
    • period 26 / run range: 81682-81696 / number of runs:14
    • period 27 / run range: 81702-81710 / number of runs:7
    • period 28 / run range: 81712-81716 / number of runs:5

Gains matching calibration monitoring plots

Checking the FCAL gains

Energy dependence correction monitoring plots

Timing calibration

Bad block map

This map is done for each run number by combining the info collected by analysing the LED and pi0 skims.