Difference between revisions of "GlueX Start Counter Meeting, January 27, 2011"

From GlueXWiki
Jump to: navigation, search
(notes as minutes)
(Minutes)
Line 36: Line 36:
 
=Minutes=
 
=Minutes=
  
* '''FIU''': Eric, Lei, Werner
+
Present:
* '''JLab''': Simon Beni Sascha Eugene Mark
+
* '''FIU''': Werner Boeglin, Lei Guo, Eric Pooser
 +
* '''JLab''': Eugene Chudakov, Mark Ito (chair), Sascha Somov, Simon Taylor, Beni Zihlmann
  
 
$190 a piece, sent to furniture company,
 
$190 a piece, sent to furniture company,

Revision as of 09:53, 28 January 2011

Location, Time

Thursday, January 27, 2011
3:30 pm EST
JLab: CEBAF Center, Room F326/7

Agenda

  1. Announcements
  2. Review minutes from previous meeting: all
  3. Start Counter News: Werner, Lei, Eric
  1. MOU plans: all

Communication Information

Telephone

To connect by telephone:

  1. dial:
  2. enter access code followed by the # sign: 3421244#

Video Conferencing

Slides

Talks can be deposited in the directory /group/halld/www/halldweb1/html/talks/2011-1Q on the JLab CUE. This directory is accessible from the web at https://halldweb1.jlab.org/talks/2011-1Q/ . You have to be a member of the "halld" Unix group to do this.

Minutes

Present:

  • FIU: Werner Boeglin, Lei Guo, Eric Pooser
  • JLab: Eugene Chudakov, Mark Ito (chair), Sascha Somov, Simon Taylor, Beni Zihlmann

$190 a piece, sent to furniture company, with diamond milled edges plastic craft : bend cut and polish

sasha: richard wrote a note estimating impact of dark current • timing resolution not much affected by rate • went to GHz • photonique recover rate gives fluctuation • hamamtsu has faster recovery rate

measurements with new SiPM • timing resolution a bit disappointing • more test with the new scintillator, with PMT ∘ light output ∘ attentuaion length • then with SiPM ∘ even with same amount of light, get factor 1.5-2 worse resolution ∘ pulse with led works well with SiPM ∘ more study needed ∘ cannot see single pe peak, pedestal is wide

50 mV signal from SiPM, amplified to 200 mV ADC uses direct signal

don't think it is the amount of light played a bit with bias voltage, nominally 71 V using what Carl ways

using cfd's

peltier element

werner will send MOU

time resolution requirement: what is it? what do we put in MOU.

E. put in purpose

W. may take some details out.

photo-detectors in a region of substantial magnetic field

sascha: use the tagger to help

total 56 K$ labor: 170 man-weeks for labor