Difference between revisions of "FCAL Backgrounds"

From GlueXWiki
Jump to: navigation, search
(Plots)
(Plots)
Line 25: Line 25:
 
[[Image:fcal_dose.jpg|frame|center|The total radiation dose per second in the FCAL.  This calculation assumes uniform deposition of energy throughout the block.  This is not actually correct since, for example, the upstream end of the block will receive a higher dose than the downstream end.]]
 
[[Image:fcal_dose.jpg|frame|center|The total radiation dose per second in the FCAL.  This calculation assumes uniform deposition of energy throughout the block.  This is not actually correct since, for example, the upstream end of the block will receive a higher dose than the downstream end.]]
  
[[Image:Radphi_radiation_damage_vs_time.gif|The plot shows the gain factor versus time for a lead glass block next to the beam hole in the Radphi experiment. The Radphi calorimeter was located 1 m downstream from the Radphi target, a small block of beryllium 0.08 radiation lengths thick. From the point of view of electromagnetic backgrounds, the Radphi photon beam is matched to GlueX running at an intensity of 80M tags/s, 80% of full-intensity running.]]
+
[[Image:Radphi_radiation_damage_vs_time.gif|frame|center|The plot shows the gain factor versus time for a lead glass block next to the beam hole in the Radphi experiment. The Radphi calorimeter was located 1 m downstream from the Radphi target, a small block of beryllium 0.08 radiation lengths thick. From the point of view of electromagnetic backgrounds, the Radphi photon beam is matched to GlueX running at an intensity of 80M tags/s, 80% of full-intensity running.]]

Revision as of 17:21, 23 January 2007

Back to Background Rate Studies


Detector Configuration

  • Double-Hit Resolution: 75 ns
  • Threshold: 2 MeV (30 MeV in repository)
  • Maximum Number of Hits: 500 (100 in repository)


Items for Discussion

  • Change threshold and maximum number of hits in repository.

The "maximum hits" being modified here is the maximum number of hits per block. Multiple hits in a single block that occur within a certain time interval (currently 75 ns) are merged into a single hit, so to exceed 100 hits in a block is essentially impossible within the time interval of the simulation. An error message appears in the output any time an event hit record is truncated because it hit the maximum hit limit, and this has not occurred in hundreds of millions of events of all kinds that I have simulated so far. So this change will have no effect. [rtj]

  • GlueX note under development to describe mechanism for background suppression in the FCAL. Timing information from the FADC will be key in removing background hits.
  • At what dose does radiation damage begin to become an issue?
    • This source cites this paper and notes a drop in response for TF1 lead glass of e after about a 2 krad dose.

Plots

The background rates in Hz for each block in the FCAL.
The total radiation dose per second in the FCAL. This calculation assumes uniform deposition of energy throughout the block. This is not actually correct since, for example, the upstream end of the block will receive a higher dose than the downstream end.
The plot shows the gain factor versus time for a lead glass block next to the beam hole in the Radphi experiment. The Radphi calorimeter was located 1 m downstream from the Radphi target, a small block of beryllium 0.08 radiation lengths thick. From the point of view of electromagnetic backgrounds, the Radphi photon beam is matched to GlueX running at an intensity of 80M tags/s, 80% of full-intensity running.