The GlueX FCAL will consist of 2800, 4 cm x 4 cm x 45 cm lead glass blocks stacked in a circular array.  Each block will be optically coupled to an FEU 84-3 PMT which will be instrumented with flash ADC electronics.
+
[[Image:fcal_array.jpg|300px]]
 +
 
 +
-----
 +
 
 +
The GlueX FCAL consists of 2800, 4 cm x 4 cm x 45 cm lead glass blocks stacked in a circular array.  Each block is optically coupled to an FEU 84-3 PMT which will be instrumented with flash ADC electronics.
 +
GlueX-doc 985,988 and 989 document the GlueX Fcal as presented in the February 2008 Calorimetry Review.
 +
 
 +
=== FCAL calibration ===
 +
* [[FCAL calibration Meeting with the AIEC team]]
 +
* Run periods
 +
** [[PrimEx-eta phase1 FCAL energy calibration]]
 +
** [[PrimEx-eta phase2 FCAL energy calibration]]
 +
** [[SRC FCAL time/energy calibrations]]
 +
** [[CPP FCAL time/energy calibrations]]
 +
** [[PrimEx-eta phase3 FCAL time/energy calibrations]]
 +
 
 +
=== Shift Taker Reference Guide ===
 +
* [https://halldweb.jlab.org/hdops/wiki/index.php/Forward_Calorimeter_Shift FCAL Reference]
 +
* [https://halldweb.jlab.org/hdops/wiki/index.php/Forward_Calorimeter_Expert Expert Page]
 +
 
 +
=== Info For Data Analyzers ===
 +
[https://halldweb.jlab.org/wiki-private/index.php/FCAL_Analysis_Summary FCAL Summary]
 +
 
 +
=== FCAL Expert Manuals ===
 +
* [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=2770 Manuel's Manual]
 +
* [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=3336 Jon's FCAL base manual]
  
 
=== Mechanical Design ===
 
=== Mechanical Design ===
  
* [[FCALCellWall]]
+
* [[FCALPhotos]]
 
* [[FCALPMT]]
 
* [[FCALPMT]]
 +
** [[Temperature tests]]
 
* [[FCALLeadGlass]]
 
* [[FCALLeadGlass]]
 
* Light Guides
 
* Light Guides
** [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=850 Light-guide simulation]
+
** [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=850 Light-guide simulation]
 
** [[Light guide tests]]
 
** [[Light guide tests]]
 
* [[Cosmic ray tests]]
 
* [[Cosmic ray tests]]
 +
 +
=== Radiation Damage ===
 +
 +
* [[IUCF Tests]]
 +
 +
=== Optical Measurements ===
 +
 +
* [[Attenuation Results from Radphi]]
 +
* [[lead glass cosmic ray tests]]
  
 
=== Electromagnetic Background ===
 
=== Electromagnetic Background ===
  
 
* [[FCAL Backgrounds]]
 
* [[FCAL Backgrounds]]
 +
 +
=== [[Options for Radiation-Hard Insert]] ===
  
 
=== Readout Electronics ===
 
=== Readout Electronics ===
  
* [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=426 Flash ADC timing algorithm]
+
[https://halldweb1.jlab.org/wiki/index.php/FCAL_Readout_Electronics Write up by Scott Teige]
 +
 
 +
=== CW Bases ===
 +
*[[Investigations and Repairs]]
 +
 
 +
=== Reconstruction ===
 +
 
 +
* Clustering algorithm from RADPHI: [http://zeus.phys.uconn.edu/radphi/nim-2-2004/NIM-6-2006/pubcopy.pdf NIM A 570 (2007) 384 ]
 +
 
 +
* Photon reconstruction: [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=823 GlueX-doc-823]
 +
 
 +
* Nonlinear energy and depth corrections [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=1093 GlueX-doc-1093]
 +
 
 +
=== Previous Experiment References ===
 +
 
 +
* GlueX uses the same lead-glass bars and PMTs as the E852 and RADPHI experiments. Some relevant NIM articles for these experiments are given here.
 +
* [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=3251 E852 Calorimeter NIM]
 +
* [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=3252 RADPHI General NIM]
 +
* [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=3253 RADPHI Calorimeter Resolution and Gain Balancing]

Revision as of 09:48, 31 October 2022

Fcal array.jpg


The GlueX FCAL consists of 2800, 4 cm x 4 cm x 45 cm lead glass blocks stacked in a circular array. Each block is optically coupled to an FEU 84-3 PMT which will be instrumented with flash ADC electronics. GlueX-doc 985,988 and 989 document the GlueX Fcal as presented in the February 2008 Calorimetry Review.

FCAL calibration

Shift Taker Reference Guide

Info For Data Analyzers

FCAL Summary

FCAL Expert Manuals

Mechanical Design

Radiation Damage

Optical Measurements

Electromagnetic Background

Options for Radiation-Hard Insert

Readout Electronics

Write up by Scott Teige

CW Bases

Reconstruction

Previous Experiment References