###* Individual threshold for each channels or common threshold : determine
 
###* Individual threshold for each channels or common threshold : determine
 
###* Control of thresholds
 
###* Control of thresholds
##* If ADC or TDC work with common threshold all gains need to be matched to assure uniform discrimination
+
##* If ADC or TDC work with common threshold all gains need to be matched to assure uniform discrimination
+
# '''Flash ADCs  Pedestals''':
Flash ADCs  Pedestals:
+
## Automatic procedure for measuring pedestals
automatic procedure for measuring pedestals
+
## On-demand when DAQ idle
on-demand when DAQ idle
+
## As part of special pedestal trigger
as part of special pedestal trigger
+
## As a part of regular data taking
as a part of regular data taking
+
## System for storing results in a database
system for storing results in a database
+
## System for tracking changes over time
system for tracking changes over time
+
## Semi-automatic procedure for setting pedestals
semi-automatic procedure for setting pedestals
+
## Make available for download after approval
make available for download after approval
+
# '''ST Channels'''
 
+
## Develop gain matching procedure
 
+
## Develop threshold setting procedure
ST Channels  
+
## Do a threshold curve for gain matched system  
develop gain matching procedure
+
# '''Bias Voltage'''
develop threshold setting procedure
+
## System for storing current values in a database (currently stored in EPICS (?), connection to CCDB?)
do a threshold curve for gain matched system  
+
### Start with FIU bench-measurement values
 
+
### Measuring relative gains of SiPM as a function of bias voltage:  
 
+
###* Use tracking & PID to select minimum ionizing & attenuation correction
Bias Voltage
+
###* Measure pedestal dependence on Bias Voltage
system for storing current values in a database (currently stored in EPICS (?), connection to CCDB?)
+
### System for gain matching for SiPM:
start with FIU bench-measurement values
+
###* Bias voltage settable for individual detectors
measuring relative gains of SiPM as a function of bias voltage:  
+
###* Develop gain matching procedure using bias voltage:
use tracking & PID to select minimum ionizing & attenuation correction
+
#### Select common criteria for event selection (position, partilce type, momentum)
measure pedestal dependence on Bias Voltage
+
####* Minimum ionizing
system for gain matching for SiPM:
+
####* Use mode 8 data sample data regularly
      bias voltage settable for individual detectors
+
####* Develop algorithm for determining new bias values
      develop gain matching procedure using bias voltage:
+
select common criteria for event selection (position, partilce type, momentum)
+
minimum ionizing
+
use mode 8 data sample data reguarly
+
develop algorithm for determining new bias values
+
 
 
  

Revision as of 15:14, 3 March 2015

  1. Minimum requirement for ST event with good timing:
    • ADC
    • TDC
    • Matched particle track
  2. Thresholds:
    1. Scalers:
      • Individual threshold for each channels or common threshold : determine
      • Control of thresholds
      1. TDC:
        • Individual threshold for each channels or common threshold : determine
        • Control of thresholds
      2. ADC:
        • Individual threshold for each channels or common threshold : determine
        • Control of thresholds
      • If ADC or TDC work with common threshold all gains need to be matched to assure uniform discrimination
  3. Flash ADCs Pedestals:
    1. Automatic procedure for measuring pedestals
    2. On-demand when DAQ idle
    3. As part of special pedestal trigger
    4. As a part of regular data taking
    5. System for storing results in a database
    6. System for tracking changes over time
    7. Semi-automatic procedure for setting pedestals
    8. Make available for download after approval
  4. ST Channels
    1. Develop gain matching procedure
    2. Develop threshold setting procedure
    3. Do a threshold curve for gain matched system
  5. Bias Voltage
    1. System for storing current values in a database (currently stored in EPICS (?), connection to CCDB?)
      1. Start with FIU bench-measurement values
      2. Measuring relative gains of SiPM as a function of bias voltage:
        • Use tracking & PID to select minimum ionizing & attenuation correction
        • Measure pedestal dependence on Bias Voltage
      3. System for gain matching for SiPM:
        • Bias voltage settable for individual detectors
        • Develop gain matching procedure using bias voltage:
        1. Select common criteria for event selection (position, partilce type, momentum)
          • Minimum ionizing
          • Use mode 8 data sample data regularly
          • Develop algorithm for determining new bias values


Scalers rates need to be in agreement with TDC/ADC rates stand-alone GUI for reading values (exists already anything new needed?)

Measure discriminator threshold with flash & w/o flash align flash, TDC and scaler rates if all devices have common threshold the gain needs to be adjusted to align all check thresholds with flash wave form data

SiPM monitoring

    design procedure for estimating photo-electrons per MeV (PID & tracking needed)
    system for storing results in a database


Efficiency Monitoring: time resolution: monitor time resolution (internal time differences between detectors) energy resolution: monitor standard dedx data signal attenuation: determine attenuation parameters. Monitor parameter variation as a function of time/rate efficiency: determine efficiency using tracking formation. system for storing time resolution, attenuation parameters and efficiency parameters in CCCDB

Timing calibration

      time-walk calibration: develop automatic procedure, monitor parameters
      signal shape characterization: regular sampling of signal shapes
      

Run preparations: establish standard procedure for data taking update online monitoring system review existing histograms suggest additions

Procedure during experiment: assess ST status: rates, efficiencies alarm handler: prepare actions according to various alarm handler events