Difference between revisions of "CPP FCAL time/energy calibrations"

From GlueXWiki
Jump to: navigation, search
(Periods)
(What is currently in the default variation)
(18 intermediate revisions by the same user not shown)
Line 6: Line 6:
  
 
== What is currently in the default variation ==
 
== What is currently in the default variation ==
 +
 +
* For the energy calibration (empty target periods used period 1 table)
 +
** period 0: 100408-100845
 +
** period 1: 100961-101010
 +
** period 2: 101011-101044
 +
** period 4: 101076-101154
 +
** period 8: 101255-101336
 +
** period 11: 101439-101587
 +
NB: the period in this section does not match the period in section "Period" but matches the period in section "Gain matching calibration plots". And the period for energy and time is not the same!
 +
* For the time calibration
 +
** period 1: 100408-100960
 +
** period 2: 100961-
  
 
== Periods ==
 
== Periods ==
  
The periods in BOLD are calibrated i.e. have a pedestal and gain tables. Each period corresponds to an arbitrary 24h block from 00:00 to 00:00+24:00. These periods do not match yet the the FCAL hardware changes. The run ranges of the FCAL hardware changes are currently in the process to be determined. The preliminary tables are in xxx variation.
+
The periods in BOLD are calibrated i.e. have a pedestal and gain tables. Each period corresponds to constant FCAL and/or experimental conditions.
 +
 
 +
* period 1: 100408-100960
 +
* period 2: 100961-101010
 +
* period 3: 101011-101044
 +
* period 4: 101045-101074 (empty target)
 +
* period 5: 101076-101154 (some blocks set to 1 in block_quality)
 +
* period 6: 101164-101166
 +
* period 7: 101167-101254 (empty target)
 +
* period 8: 101255-101336
 +
* period 9: 101337-101392 (Hall B half-wave plate in)
 +
* period 10: 101393-101402 (Hall B half-wave plate in & empty target)
 +
* period 11: 101403-101438 (empty target)
 +
* period 12: 101439-101529
 +
* period 13: 101530-101535 (Hall B half-wave plate in)
 +
* period 14: 101536-101587
 +
* period 15: 101597-101609 (empty target)
  
 
== Gain matching calibration plots ==
 
== Gain matching calibration plots ==
Line 20: Line 48:
  
 
== Timing calibration ==
 
== Timing calibration ==
 +
* period 1: 100408-100960
 +
* period 2: 100961-
  
 
== Bad block map ==
 
== Bad block map ==
  
 
This map is done for each run number by combining the info collected by analysing the LED and pi0 skims.
 
This map is done for each run number by combining the info collected by analysing the LED and pi0 skims.

Revision as of 17:50, 23 August 2022

List of changes

These lists are giving the run ranges where the FCAL hardware was not changed.

Monitoring results

What is currently in the default variation

  • For the energy calibration (empty target periods used period 1 table)
    • period 0: 100408-100845
    • period 1: 100961-101010
    • period 2: 101011-101044
    • period 4: 101076-101154
    • period 8: 101255-101336
    • period 11: 101439-101587

NB: the period in this section does not match the period in section "Period" but matches the period in section "Gain matching calibration plots". And the period for energy and time is not the same!

  • For the time calibration
    • period 1: 100408-100960
    • period 2: 100961-

Periods

The periods in BOLD are calibrated i.e. have a pedestal and gain tables. Each period corresponds to constant FCAL and/or experimental conditions.

  • period 1: 100408-100960
  • period 2: 100961-101010
  • period 3: 101011-101044
  • period 4: 101045-101074 (empty target)
  • period 5: 101076-101154 (some blocks set to 1 in block_quality)
  • period 6: 101164-101166
  • period 7: 101167-101254 (empty target)
  • period 8: 101255-101336
  • period 9: 101337-101392 (Hall B half-wave plate in)
  • period 10: 101393-101402 (Hall B half-wave plate in & empty target)
  • period 11: 101403-101438 (empty target)
  • period 12: 101439-101529
  • period 13: 101530-101535 (Hall B half-wave plate in)
  • period 14: 101536-101587
  • period 15: 101597-101609 (empty target)

Gain matching calibration plots

Checking the FCAL gains

Energy dependence correction monitoring plots

Timing calibration

  • period 1: 100408-100960
  • period 2: 100961-

Bad block map