CDC old & new preamp noise scope trace study

From GlueXWiki
Revision as of 16:41, 30 June 2010 by Yvhaarle (Talk | contribs)

Jump to: navigation, search

A study was performed using three preAmps:

  • Yves' old preAmp : the old preamp that changed behavior a month ago
  • Beni's old preAmp: the old preamp used before by Beni.
  • Naomi's preAmp  : the new preAmp.

Left is always Yves' old preAmp, middle is Beni's old preAmp, right is Naomi's new preAmp [except mentioned differently]

First 2000V was put on the chamber and a random cosmic ray signal was selected:

Yves' old preamp - 2000V - cosmic ray
Beni's old preamp - 2000V - cosmic ray
Naomi's new preamp - 2000V - cosmic ray


OK, so far so good. Let's switch the HV off and look at the ringing: the highest amplitude ringing was selected, so you are looking at the high end of the pedestal:

Channel 1

Yves' old preamp - ch1 - ringing
Beni's old preamp - ch1 - ringing
Naomi's new preamp - ch1 - ringing

Channel 8

Yves' old preamp - ch8 - ringing
Beni's old preamp - ch8 - ringing
Naomi's new preamp - ch8 - ringing

Channel 9

Yves' old preamp - ch9 - ringing
Beni's old preamp - ch9 - ringing
Naomi's new preamp - ch9 - ringing

Channel 15 <- This channel is always used for Fe-55 measurements

Yves' old preamp - ch15 - ringing
Beni's old preamp - ch15 - ringing
Naomi's new preamp - ch15 - ringing

The old preAmp has higher amplitude noise in chip2 -> channels 9-16 The new preamp has lower amplitude ringing compared to the old preAmp.


Now it comes: wierd peaks (see below) are seen in the Fe-55 spectra in yves' old preAmp and Beni's old preAmp. This is because those when those spectra are taken the straw is self triggering.

Yves' old preamp - Fe-55 - with weird peaks around channel 1000. The peak on the left might be the ringing shown above.
Beni's old preamp - Fe-55 - with weird (double) peaks around channel 1000

This is how it looks on the scope: (the new preAmp did not show this behavior) Channel 1

Yves' old preamp - ch1 - weird peak
Beni's old preamp - ch1 - weird peak

Channel 8

Yves' old preamp - ch8 - weird peak
Beni's old preamp - ch8 - weird peak

Channel 9

Yves' old preamp - ch9 - weird peak
Beni's old preamp - ch9 - weird peak

Channel 15 <- channel used for Fe-55 measurements

Yves' old preamp - ch15 - weird peak
Beni's old preamp - ch15 - weird peak

The HV board was also changed but this did not make any difference. We think this behavior is a sign that the old preAmp is broken.

These peaks were not seen in yves' old preAmp months ago. We know this because at at some point we had to increase the internal threshold of the straw to do Fe-55 measurements with the old preAmp. Also, they would have showed up in the Fe-55 spectra (see below)

Question remains: what happened to go from this situation:

amplitude: Yves' old preamp months ago, 55Fe, 50/50 Ar/CO2, 2100V, 2009

to this

|width="415pt"|
amplitude: Yves' old preamp, 55Fe, 50/50 Ar/CO2, 2100V, 2010

|}