This page summarizes various studies used to try to understand backgrounds produced in the detector from the 9 GeV coherent brem. beam that enters Hall D.
 
This page summarizes various studies used to try to understand backgrounds produced in the detector from the 9 GeV coherent brem. beam that enters Hall D.
  
Line 7: Line 6:
  
 
== CDC ==
 
== CDC ==
 +
 +
Detector Configuration:
 +
 +
* Double-Hit Resolution:  250 ns
 +
* Threshold: 1 keV
 +
* Maximum Number of Hits (per Event):  100

Revision as of 13:56, 18 December 2006

This page summarizes various studies used to try to understand backgrounds produced in the detector from the 9 GeV coherent brem. beam that enters Hall D.

Simulation Information

A total of 10e8 9 GeV beam photons (1 second of beam time) were generated using the geometry and simulation current as of approx. December 1. Note that various hit thresholds exist for each detector system. Noise count rates are highly dependent on these thresholds.

CDC

Detector Configuration:

  • Double-Hit Resolution: 250 ns
  • Threshold: 1 keV
  • Maximum Number of Hits (per Event): 100