April 6, 2016 Calibration

From GlueXWiki
Revision as of 13:28, 6 April 2016 by Sdobbs (Talk | contribs) (Agenda)

Jump to: navigation, search

GlueX Calibration Meeting
Wednesday, April 6, 2016
11:00 am, EST
JLab: CEBAF Center, F326

Communication Information

Remote Connection

You can connect using BlueJeans using the meeting number 630 804 895 .       (Click "Expand" to the right for more details -->):

  1. Make sure you have created a BlueJeans account via your JLab CUE account using this link:

  2. Meeting ID: 630804895
    • (you may need to type this in, depending how you connect)

  3. If connecting via Web Browser: click this link (no passcode is needed):

  4. If connecting via iOS or Android App:
    • Use your JLab e-mail address to log in and then enter the meeting ID given above to join the meeting

  5. If connecting via Phone: Dial one of the following numbers and then enter the meeting ID above and hit "#" or "##"

  6. If connecting via Polycom unit:
    • Dial 199.48.152.152 or bjn.vc
    • Enter meeting ID above
    • Use *4 to unmute

Slides

Talks can be deposited in the directory /group/halld/www/halldweb/html/talks/2016 on the JLab CUE. This directory is accessible from the web at https://halldweb.jlab.org/talks/2016/ .

Agenda

  1. Announcements
  2. Subdetector Reports
  3. Calibration Tasks
  4. Simulations
  5. AOB

Minutes

Attending: Sean (NU); Simon, Eugene, Curtis, Paul M., Adesh, Alex B., George, Luke, Beni, Nathan, Lubomir, Mark D., Elton (JLab); Mahmoud (FIU); Mike S., Naomi (CMU); Matt S. (IU)

  1. Announcements
    • Paul has been looking into the cause of the poor thread scaling behavior he reported at last week's Offline meeting. The global ROOT lock used for histogram filling is the problem. Tried disabling the locks for part of the running, but this ran into crashes. Has devised a scheme to improve the situation with David L., requires a new version of JANA and changes to sim-recon wherever histograms are filled.
    • Paul plans to launch another round of monitoring on Friday, if the above changes are finished. The other big slowdown was kinematic fitting in the exclusive reaction plugins; this will be disabled. A higher TAGM threshold will be used, since the current REST files are swamped with background in this range; ~30% of hits have two microscope hits.
    • The first set of calibration jobs has finished, including calorimeter and TOF skims; Sean has started a new set of jobs over the 3.4 mm collimator data.
    • Sean has been keeping up with timing calibration corrections over the past few weeks. Generally these have been stable, with small changes due to calorimeter trigger studies. Lubomir changed the FDC hold off time by 80 ns, which led to forward going tracks being reconstructed with bad chi^2. Sean fixed this using the eyeball technique, having a better defined procedure for FDC times would be more helpful.
    • Mark Ito set up a GlueX software help email list. Paul stated that he won't answer any more direct email questions, and will forward them to the list.
  2. Subdetector Reports
    • FCAL - Mike's recent changes to the DAQ library corrected the number of pedestal samples that were being used, so Adesh is in the process of updating the gain calibrations (it was previously noted that the pi0 peak had shifted to lower mass). He is running over the official pi0 skims, using 3 M pi0s to get an initial calibration before the monitoring launch. It takes him ~8 hours to do an iteration, which is a ~3x speed increase.
    • BCAL - Substantial changes to the clustering algorithm are being finalized. Will is working on updating gain calibrations, and George's quadratically fitted effective velocities have been added to the CCDB. After discussion, we agreed that these improvements should be checked in after the monitoring launch.
    • CDC - Mike showed some slides comparing wire efficiencies and resolutions. Simulation (sigma ~ 150 um) and cosmics (sigma ~ 120um) agree reasonably well, but beam data looks worse (sigma ~ 210um). Probably the t0 calculation (SC?) is off? Mike is looking at the causes. The long tails are due to multiple scattering.
    • Resolution & Efficiency updates
    • CDC Comparison MC Data
    • PS energy calibration
    • TPOL analysis
  3. Calibration Tasks
  4. Simulations
  5. AOB