File:Radphi radiation damage vs time.gif

From GlueXWiki
Jump to: navigation, search
Radphi_radiation_damage_vs_time.gif(567 × 567 pixels, file size: 357 KB, MIME type: image/gif)

The plot shows the gain factor versus time for a lead glass block next to the beam hole in the Radphi experiment. The Radphi calorimeter was located 1 m downstream from the Radphi target, a small block of beryllium 0.08 radiation lengths thick. From the point of view of electromagnetic backgrounds, the Radphi photon beam is matched to GlueX running at an intensity of 80M tags/s, 80% of full-intensity running.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current17:18, 23 January 2007Thumbnail for version as of 17:18, 23 January 2007567 × 567 (357 KB)Jonesrt (Talk | contribs)The plot shows the gain factor versus time for a lead glass block next to the beam hole in the Radphi experiment. The Radphi calorimeter was located 1 m downstream from the Radphi target, a small block of beryllium 0.08 radiation lengths thick. From the