Difference between revisions of "TOF Performance"

From GlueXWiki
Jump to: navigation, search
(Created page with "== TOF Performance == A measure of the TOF performance is the width to the pion beta(v/c) distribution as a function of momentum. The smaller this number the better protons ca...")
 
(TOF Performance)
Line 1: Line 1:
 
== TOF Performance ==
 
== TOF Performance ==
A measure of the TOF performance is the width to the pion beta(v/c) distribution as a function of momentum. The smaller this number the better protons can be separated from pions at higher momenta. It was found that using a single fixed effective velocity for all paddles in the TOF detector yields a better performance then using individual values for this velocity as determined from calibration of the TOF. To demonstrate this the following two plots show the beta of positive particles in TOF with a momentum of 4 GeV/c. The first pictures shows  data from run 72840 with database parameters from Jul 2021 where each paddle had a separate velocity while the second plot shows the same data but with a single velocity for all paddles:
+
A measure of the TOF performance is the width to the pion beta(v/c) distribution as a function of momentum. The smaller this number the better protons can be separated from pions at higher momenta. It was found that using a single fixed effective velocity for all paddles in the TOF detector yields a better performance then using individual values for this velocity as determined from calibration of the TOF. To demonstrate this the following two plots show the beta of positive particles in TOF with a momentum of 4 GeV/c. The first pictures shows  data from run 72840 with database parameters from Jul 2021 where each paddle had a separate velocity while the second plot shows the same data but with a single velocity for all paddles:<br>
 +
'''Run 72840 with variable effective velocity'''<br>
 
[[File:tof_performance_Jul2021.png | 300px]]   
 
[[File:tof_performance_Jul2021.png | 300px]]   
  
 +
 +
'''Run 72840 with variable effective velocity'''<br>
 
[[File:tof_performance_apr2021.png | 300px]]
 
[[File:tof_performance_apr2021.png | 300px]]

Revision as of 08:41, 30 April 2024

TOF Performance

A measure of the TOF performance is the width to the pion beta(v/c) distribution as a function of momentum. The smaller this number the better protons can be separated from pions at higher momenta. It was found that using a single fixed effective velocity for all paddles in the TOF detector yields a better performance then using individual values for this velocity as determined from calibration of the TOF. To demonstrate this the following two plots show the beta of positive particles in TOF with a momentum of 4 GeV/c. The first pictures shows data from run 72840 with database parameters from Jul 2021 where each paddle had a separate velocity while the second plot shows the same data but with a single velocity for all paddles:
Run 72840 with variable effective velocity
Tof performance Jul2021.png


Run 72840 with variable effective velocity
Tof performance apr2021.png