Difference between revisions of "Private:UConn test setup"
From GlueXWiki
Line 1: | Line 1: | ||
+ | In the DAQ crate we are using an old Trigger Interface (TI) board, i.e. the triggers are distributed through | ||
+ | boards front pannels. The SDC board is used for the trigger distribution to fadc250. | ||
+ | |||
''' Boards in the crate''' | ''' Boards in the crate''' | ||
Revision as of 14:51, 24 September 2012
In the DAQ crate we are using an old Trigger Interface (TI) board, i.e. the triggers are distributed through boards front pannels. The SDC board is used for the trigger distribution to fadc250.
Boards in the crate
Board | Slot | Serial |
---|---|---|
CPU (halldtrg5) | 1 | |
TI (Old) | 2 | |
FADC250 | 5 | B21595_06R |
SDC | 9 | |
LE discriminator | 14 | C_15 |
F1TDC | 16 |
Front pannel connections
From | To |
---|---|
External trigger | TI input, IN1 |
L1 Accept ( 3rd from the bottom ) | SDC TRG |
L1 Accept ( 4 th from the bottom ) | F1TDC TRG |
TI Out0 | F1TDC SYNC |
Setting up the setup
- Connect keybord and monitor (if needed) to the Intel ROC.
- Connect Ethernet cable to the upper ROC LAN connector.
- Change ROC IP address (you will see the MAC address when you start booting the controller)
- Login under halld
Directories
Most DAQ files (CODA), the Run Control and other applications have been installed localy on the ROC flash disc. You will need to mount the remote data disc to store data files.
Below is a description of some directories:
- The home directory is /home/halld
- /home/halld/micro/rol contains the F1TDC configuration file and the link to the DAC readout list (see descriptions below)
- /home/halld/micro/coda contains Run Control data base
- /home/halld/data is a directory for the DAQ data storage. The external drive has to be mounted to here
- /home/halld/micro/coda_micro_setup is a script with configuration variables
- you have to edit this file ad change some variables if needed
- source coda_micro_setup to set variables up
- Coda and Run Control files are installed at /usr/local/coda/2.6.1
How to run DAQ
Change electronics boards initialization parameters